BRAKE BOOSTER > INSTALLATION |
| 1. INSTALL BRAKE MASTER CYLINDER PUSH ROD CLEVIS |
Temporarily install the lock nut and the brake master cylinder push rod clevis to the brake booster assembly.
| 2. INSTALL BRAKE BOOSTER GASKET |
![]() |
Install a new brake booster gasket.
| 3. INSTALL BRAKE BOOSTER ASSEMBLY |
![]() |
Install the brake booster assembly and the gasket with the 4 nuts.
| 4. CONNECT NO. 2 VACUUM HOSE (for 2AZ-FE RHD) |
![]() |
Connect the No. 2 vacuum hose and move the clip.
| 5. INSTALL BRAKE MASTER CYLINDER SUB-ASSEMBLY |
| 6. CONNECT NO. 2 VACUUM HOSE (for LHD) |
![]() |
Connect the No. 2 vacuum hose and move the clip.
| 7. CONNECT BRAKE MASTER CYLINDER PUSH ROD CLEVIS |
![]() |
Apply the lithium soap base glycol grease to the push rod pin.
Connect the brake master cylinder push rod clevis to the brake pedal with the push rod pin and a new clip as shown in the illustration.
| 8. INSTALL BRAKE PEDAL RETURN SPRING (for LHD) |
![]() |
Install the brake pedal return spring.
| 9. INSTALL BRAKE PEDAL RETURN SPRING (for RHD) |
![]() |
Install the brake pedal return spring.
| 10. CONNECT BRAKE LINE (for RHD) |
![]() |
Install the brake lines to the clamp.
Connect the 6 brake lines.
Without VSC
With VSC
| 11. CONNECT AIR CONDITIONING TUBE AND ACCESSORY (for RHD) |
Remove the attached vinyl tape from the tube.
Sufficiently apply compressor oil to a new O-ring and fitting surface of the air conditioning tube assembly.
Install the O-ring on the air conditioning tube and accessory.
Install the air conditioner tube and accessory.
| 12. CONNECT SUCTION PIPE SUB-ASSEMBLY (for RHD) |
Remove the attached vinyl tape from the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the suction hose sub-assembly.
Install the O-ring on the suction hose sub-assembly.
![]() |
Move the hook connector in the direction indicated by the arrow in the illustration.
Insert the pipe joint into the fitting hole securely and tighten the bolt.
| 13. INSTALL ENGINE AND TRANSAXLE (for 2GR-FE RHD) |
| 14. CHARGE WITH REFRIGERANT (for RHD) |
Perform vacuum purging using a vacuum pump.
Charge with refrigerant HFC-134a (R134a).

| 15. CHECK FOR LEAKAGE OF REFRIGERANT (for RHD) |
After recharging with refrigerant gas, check for leakage of refrigerant gas using a halogen leak detector.
Carry out the test under the following conditions:
![]() |
Using a gas leak detector, check for leakage from the refrigerant lines.
![]() |
Bring the gas leak detector close to the drain hose with the detector's power off, and then turn the detector on.
If a gas leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.