DTC B2342 Switch Failure |
| DTC No. | DTC Detection Condition | Trouble Area |
| B2342 | Sliding roof drive gear sub-assembly (sliding roof control ECU) detects OPEN, CLOSE, UP, or DOWN switch in overhead junction block is stuck for 30 seconds or more |
|
| 1.READ VALUE ON INTELLIGENT TESTER (SLIDE OPEN AND TILT UP SWITCH) |
Use the DATA LIST to check if the sliding roof switch is functioning properly.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Open SW (Open Switch) | Slide switch open signal/ON or OFF | ON: OPEN switch is pressed. OFF: OPEN switch is not pressed. | - |
| Close SW (Close Switch) | Slide switch close signal/ON or OFF | ON: CLOSE switch is pressed. OFF: CLOSE switch is not pressed. | - |
| Up SW (Up Switch) | Tilt switch up signal/ON or OFF | ON: UP switch is pressed. OFF: UP switch is not pressed. | - |
| Down SW (Down Switch) | Tilt switch down signal/ON or OFF | ON: DOWN switch is pressed. OFF: DOWN switch is not pressed. | - |
|
| ||||
| OK | |
| 2.CHECK SLIDING ROOF FUNCTION |
Check the auto operation with the OPEN, CLOSE, UP, and DOWN switches (Click here).
|
| ||||
| OK | |
| 3.DELETE DTC |
Delete the DTCs (Click here).
| NEXT | ||
| ||
| 4.INSPECT ROOF CONSOLE BOX ASSEMBLY (SLIDING ROOF CONTROL SWITCH) |
![]() |
Remove the roof console box assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Position | Specified Condition |
| Q6-1 (CLS) - Q6-3 (GND) | CLOSE | Below 100 Ω |
| Q6-2 (OPN) - Q6-3 (GND) | OPEN | Below 100 Ω |
| Q6-4 (DOWN) - Q6-3 (GND) | DOWN | Below 100 Ω |
| Q6-5 (UP) - Q6-3 (GND) | UP | Below 100 Ω |
| Q6-1 (CLS) - Q6-3 (GND) | OPEN | 1 kΩ or higher |
| Q6-2 (OPN) - Q6-3 (GND) | CLOSE | 1 kΩ or higher |
| Q6-4 (DOWN) - Q6-3 (GND) | UP | 1 kΩ or higher |
| Q6-5 (UP) - Q6-3 (GND) | DOWN | 1 kΩ or higher |
|
| ||||
| NG | |
| 5.REPLACE ROOF CONSOLE BOX ASSEMBLY (SLIDING ROOF CONTROL SWITCH) |
Temporarily replace the roof console box assembly (sliding roof control switch) with a new one or normally functioning one .
| NEXT | |
| 6.DELETE DTC |
Delete the DTCs (Click here).
| NEXT | ||
| ||
| 7.INITIALIZE SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY (SLIDING ROOF CONTROL ECU) |
Check that the sliding roof drive gear sub-assembly can be initialized (Click here).
|
| ||||
| OK | |
| 8.CHECK SLIDING ROOF FUNCTION |
Check the auto operation with the OPEN, CLOSE, UP, and DOWN switches (Click here).
|
| ||||
| OK | |
| 9.DELETE DTC |
Delete the DTCs (Click here).
| NEXT | ||
| ||
| 10.CHECK WIRE HARNESS (SLIDING ROOF CONTROL ECU - ROOF CONSOLE BOX ASSEMBLY) |
![]() |
Disconnect the Q12 and Q6 connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q12-2 (E) - Q6-3 (GND) | Always | Below 1 Ω |
| Q12-7 (OPN) - Q6-2 (OPN) | Always | Below 1 Ω |
| Q12-8 (DWN) - Q6-4 (DOWN) | Always | Below 1 Ω |
| Q12-9 (CLS) - Q6-1 (CLS) | Always | Below 1 Ω |
| Q12-10 (UP) - Q6-5 (UP) | Always | Below 1 Ω |
| Q6-1 (CLS) - Body ground | Always | 10 kΩ or higher |
| Q6-2 (OPN) - Body ground | Always | 10 kΩ or higher |
| Q6-3 (GND) - Body ground | Always | Below 1 Ω |
| Q6-4 (DOWN) - Body ground | Always | 10 kΩ or higher |
| Q6-5 (UP) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||