HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  CHECK MODE PROCEDURE  


REFRIGERANT SHORTAGE CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC)


E239296
0.778,0.151 0.968,0.301 0.191,0.15 10 *A 4.291,0.151 4.482,0.301 0.191,0.15 10 *B
*A for LHD *B for RHD


a.

Start the engine.


b.

Check that A/C switch indicator is turned on when the following conditions are met.

Measurement Condition
Item Condition
A/C Switch On
A/C operation time 15 minutes or more
Ambient temperature* 0 to 49°C (32 to 120°F)
Engine coolant temperature 45°C (113°F) or more

*: If the ambient temperature is not within the range shown, do not perform this check.

HINT:

The A/C switch indicator and air conditioning system turn off if the amount of refrigerant in the system is insufficient.



c.

Connect the intelligent tester to the DLC3.


d.

Check for DTC B14B8.

Result
Result Amount of Refrigerant Corrective Action
DTC B14B8 is output Empty or nearly empty Check for refrigerant leaks using a halogen leak detector, and repair if necessary.
Click here(Click here)
DTC B14B8 is not output Correct or insufficient Perform a refrigerant shortage check using the intelligent tester.



REFRIGERANT SHORTAGE CHECK USING THE INTELLIGENT TESTER


a.

Connect the intelligent tester to the DLC3.


b.

Start the engine.


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Utility / Refrigerant Shortage Check.


e.

According to the display on the intelligent tester, perform the refrigerant shortage check when the following conditions are met.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 121 2186
Measurement Condition
Item Condition
A/C Switch On
Ambient temperature* 0 to 49°C (32 to 120°F)
R/F Switch Recirculation (Ambient temperature is 31°C (87°F) or less)
Fresh (Ambient temperature is 30°C (86°F) or more)
Blower Speed HI
Temperature Setting MAX HOT

*: If the ambient temperature is not within the range shown, do not perform this check.

HINT:
·

Refer to the intelligent tester operator's manual for further details.

·

A message indicating a refrigerant shortage is displayed on the intelligent tester and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.

·

DTCs are not stored when performing the refrigerant shortage check using the intelligent tester.



Result
Result Amount of Refrigerant Corrective Action
Refrigerant shortage Insufficient or leakage
1.

Check for refrigerant leaks using a halogen leak detector, and repair if necessary.

Click here(Click here)

2.

Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.


Refrigerant correct Correct -