The ambient temperature sensor (thermistor assembly) is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioning system. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor (thermistor assembly) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the ambient temperature sensor (thermistor assembly) and reads voltage changes due to changes in the resistance of the ambient temperature sensor (thermistor assembly).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1412 | Ambient Temperature Sensor Circuit | Open or short in ambient temperature sensor (thermistor assembly) circuit | ·
Ambient temperature sensor (thermistor assembly) ·
Harness or connector between ambient temperature sensor (thermistor assembly) and air conditioning amplifier assembly ·
Air conditioning amplifier assembly |
Memorized
(4 sec. or more)*1 |
*1: The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the brackets.
If the ambient temperature is approx. -52.9°C (-63.22°F) or lower, DTC B1412 may be output even though the system is normal.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Ambient temperature sensor (thermistor assembly) | Min: -23.30°C (-9.94°F)
Max: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Tester Display |
|---|
| Ambient Temp Sensor |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
C
Remove the ambient temperature sensor (thermistor assembly).
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL
| *a | Component without harness connected
(Ambient Temperature Sensor (Thermistor Assembly)) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Temperature (°C(°F)) |
| *e | Allowable Range |
Disconnect the A3 ambient temperature sensor (thermistor assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A3-1 (-) - A3-2 (+) | 10°C (50°F) | 3.00 to 3.73 kΩ |
| A3-1 (-) - A3-2 (+) | 15°C (59°F) | 2.45 to 2.88 kΩ |
| A3-1 (-) - A3-2 (+) | 20°C (68°F) | 1.95 to 2.30 kΩ |
| A3-1 (-) - A3-2 (+) | 25°C (77°F) | 1.60 to 1.80 kΩ |
| A3-1 (-) - A3-2 (+) | 30°C (86°F) | 1.28 to 1.47 kΩ |
| A3-1 (-) - A3-2 (+) | 35°C (95°F) | 1.00 to 1.22 kΩ |
| A3-1 (-) - A3-2 (+) | 40°C (104°F) | 0.80 to 1.00 kΩ |
| A3-1 (-) - A3-2 (+) | 45°C (113°F) | 0.65 to 0.85 kΩ |
| A3-1 (-) - A3-2 (+) | 50°C (122°F) | 0.50 to 0.70 kΩ |
| A3-1 (-) - A3-2 (+) | 55°C (131°F) | 0.44 to 0.60 kΩ |
| A3-1 (-) - A3-2 (+) | 60°C (140°F) | 0.36 to 0.50 kΩ |
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I77 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I77-5 (TAM) - A3-2 (+) | Always | Below 1 Ω |
| I77-13 (SG-2) - A3-1 (-) | Always | Below 1 Ω |
| I77-5 (TAM) - Body ground | Always | 10 kΩ or higher |
| I77-13 (SG-2) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG