The main body ECU (multiplex network body ECU) controls the low beam headlights.
Inspect the fuses and bulbs for circuits related to this system before performing the following inspection procedure.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Active Test.
Check that the relay operates.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Headlight Relay | Headlight relay (low beam headlights) | ON/OFF | - |
| Tester Display |
|---|
| Headlight Relay |
Headlight relay operates. (Low beam headlights illuminate.)
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the H-LP relay from the engine room relay block and junction block assembly.
| *a | Component without harness connected
(H-LP relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Voltage applied between terminals 1 and 2 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay Terminal 2 - Body ground | Always | 11 to 14 V |
| Relay Terminal 5 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A76*1 or A74*2 headlight assembly LH connector.
Disconnect the A78*1 or A75*2 headlight assembly RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay Terminal 3 - A76-11 (LO) | Always | Below 1 Ω |
| Relay Terminal 3 - A78-11 (LO) | Always | Below 1 Ω |
| Relay Terminal 3 - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay Terminal 3 - A74-1 (LO) | Always | Below 1 Ω |
| Relay Terminal 3 - A75-1 (LO) | Always | Below 1 Ω |
| Relay Terminal 3 - Body ground | Always | 10 kΩ or higher |
*1: for LHD
*2: for RHD
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3D instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay Terminal 1 - 3D-12 | Always | Below 1 Ω |
| Relay Terminal 1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3D-12 - MB-15 (HRLY) | Always | Below 1 Ω |
| 3D-12 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG