Home › Drivetrain › U760E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM
RM19V0EQ _52 Drivetrain _014582 U760E AUTOMATIC TRANSMISSION / TRANSAXLE _0076198 AUTOMATIC TRANSAXLE SYSTEM C

U760E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2716  Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)  


DESCRIPTION

Refer to the system description for DTC P2714 (See page Drivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>P2714).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
·

Open or short in shift solenoid valve SLT circuit

·

Shift solenoid valve SLT

·

Wiring harness connector

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM

C239277E11
5.656,4.333 6.083,4.521 0.427,0.188 10 ECM 5.104,1.229 5.531,1.417 0.427,0.188 10 SLT+ 5.104,2.635 5.531,2.823 0.427,0.188 10 SLT- 3.615,1.25 4.042,1.438 0.427,0.188 10 SLT+ 3.615,2.646 4.042,2.833 0.427,0.188 10 SLT- 1.604,1.927 2.542,2.26 0.938,0.333 10 Shift Solenoid Valve SLT 1.125,3.417 2.479,3.604 1.354,0.188 10 Automatic Transaxle 3.052,3.427 4.052,3.781 1,0.354 10 Wiring Harness Connector 3.094,1.25 3.521,1.438 0.427,0.188 10 SLT+ 3.094,2.646 3.521,2.833 0.427,0.188 10 SLT- 2.302,1.25 2.729,1.438 0.427,0.188 10 SLT+ 2.302,2.646 2.729,2.833 0.427,0.188 10 SLT- 5.656,4.177 5.938,4.333 0.281,0.156 10 E26 4.802,1.24 5,1.396 0.198,0.156 10 15 4.802,2.635 5,2.792 0.198,0.156 10 14 2.854,2.552 2.979,2.719 0.125,0.167 10 7 2.802,1.167 3,1.323 0.198,0.156 10 12 4.125,2.552 4.26,2.719 0.135,0.167 10 7 4.073,1.167 4.271,1.323 0.198,0.156 10 15 2.844,2.76 3.125,2.917 0.281,0.156 10 A 2.844,1.375 3.125,1.531 0.281,0.156 10 A 4.063,2.76 4.344,2.917 0.281,0.156 10 E8 4.073,1.365 4.354,1.521 0.281,0.156 10 E8

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLT CIRCUIT)
a.
C233488C31
1.469,0.323 1.958,0.615 0.49,0.292 1.458,1.052 1.688,1.75 1.688,1.75 1.844,1.75 false 1.385,1.052 1.156,1.76 1.156,1.76 1,1.76 false 0.104,0.063 0.344,0.26 0.24,0.198 10 *a 0.646,1.677 1.042,1.844 0.396,0.167 10 SLT- 1.896,1.667 2.292,1.833 0.396,0.167 10 SLT+ 1.583,0.385 1.844,0.563 0.26,0.177 10 E26
*a Front view of wire harness connector
(to ECM)


Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E26-15 (SLT+) - E26-14 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
E26-15 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
E26-14 (SLT-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
2.CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
a.

Disconnect the harness connector from the wiring harness connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E26-15 (SLT+) - E8-15 (SLT+) Always Below 1 Ω
E26-14 (SLT-) - E8-7 (SLT-) Always Below 1 Ω
E26-15 (SLT+) or E8-15 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
E26-14 (SLT-) or E8-7 (SLT-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.INSPECT TRANSMISSION WIRE (SLT)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT TRANSMISSION WIRE (SLT)
a.
C133212C06
2.386,1.064 2.741,1.214 0.355,0.149 10 SLT+ 2.386,0.345 2.718,0.495 0.332,0.149 10 SLT- 1.783,0.715 2.349,0.433 false 1.912,0.964 2.356,1.15 false 0.66,0.297 0.992,0.447 0.332,0.149 10 *a 2.307,0.656 2.794,0.948 0.487,0.292 2.483,0.712 2.671,0.894 0.187,0.182 10 A
*a Component without harness connected
(Transmission Wire)


Remove the wiring harness connector from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-12 (SLT+) - A-7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
A-12 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
A-7 (SLT-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

4.INSPECT SHIFT SOLENOID VALVE SLT
4.INSPECT SHIFT SOLENOID VALVE SLT
a.
C201747C02
1.49,0.875 0.635,0.646 false 1.781,0.865 2.479,0.625 false 1.49,3.125 0.635,2.896 false 1.781,3.125 2.479,2.885 false 0.49,0.521 0.667,0.719 0.177,0.198 10 1 2.531,0.5 2.708,0.698 0.177,0.198 10 2 1.177,4.198 1.385,4.406 0.208,0.208 10 (-) 1.917,4.208 2.146,4.406 0.229,0.198 10 (+) 0.51,2.771 0.688,2.969 0.177,0.198 10 1 2.521,2.76 2.698,2.958 0.177,0.198 10 2 0.135,0.135 0.354,0.344 0.219,0.208 10 *1
*1 Shift Solenoid Valve SLT


Remove shift solenoid valve SLT.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.

OK:

Valve moves and makes an operating sound.



Result:
Proceed to
OK
NG



OK

NG