Refer to the system description for DTC P2714 (See page Drivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>P2714).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2716 | Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic). | ·
Open or short in shift solenoid valve SLT circuit ·
Shift solenoid valve SLT ·
Wiring harness connector ·
ECM |
Comes on | DTC stored |
When an open or short in the shift solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.
| *a | Front view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E26-15 (SLT+) - E26-14 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| E26-15 (SLT+) - Body ground and other terminals | Always | 10 kΩ or higher |
| E26-14 (SLT-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the harness connector from the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E26-15 (SLT+) - E8-15 (SLT+) | Always | Below 1 Ω |
| E26-14 (SLT-) - E8-7 (SLT-) | Always | Below 1 Ω |
| E26-15 (SLT+) or E8-15 (SLT+) - Body ground and other terminals | Always | 10 kΩ or higher |
| E26-14 (SLT-) or E8-7 (SLT-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Transmission Wire) |
Remove the wiring harness connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-12 (SLT+) - A-7 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| A-12 (SLT+) - Body ground and other terminals | Always | 10 kΩ or higher |
| A-7 (SLT-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE ASSEMBLY>COMPONENTS
NG
| *1 | Shift Solenoid Valve SLT |
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
Valve moves and makes an operating sound.
| Proceed to |
|---|
| OK |
| NG |
OK
NG