Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1413/13    Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The evaporator temperature sensor (No. 1 cooler thermistor) is installed on the evaporator in the air conditioner unit to detect the temperature of the air that has passed through the evaporator and is used to control the air conditioning. It sends signals to the air conditioning amplifier assembly. The resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the evaporator temperature sensor (No. 1 cooler thermistor) and reads voltage changes as the resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes. This sensor is used for frost prevention.

DTC No.
DTC Detection Condition
Trouble Area
B1413/13
Open or short in evaporator temperature sensor (No. 1 cooler thermistor) circuit
  1. Evaporator temperature sensor (No. 1 cooler thermistor)
  2. Air conditioning harness assembly
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E229251E10


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Air Conditioner / Data List.

  1. Check the value(s) by referring to the table below.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Evaporator Fin Thermistor
    Evaporator temperature sensor (No. 1 cooler thermistor) /
    Min.: -29.70°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature displayed
    -

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
A


2.INSPECT EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR)
  1. Remove the evaporator temperature sensor (No. 1 cooler thermistor) (Click here).



    E138242E87
  1. Disconnect the a1 evaporator temperature sensor (No. 1 cooler thermistor) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    a1-1 - a1-2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    a1-1 - a1-2
    -5°C (23°F)
    5.65 to 6.95 kΩ
    a1-1 - a1-2
    0°C (32°F)
    4.40 to 5.35 kΩ
    a1-1 - a1-2
    5°C (41°F)
    3.40 to 4.15 kΩ
    a1-1 - a1-2
    10°C (50°F)
    2.70 to 3.25 kΩ
    a1-1 - a1-2
    15°C (59°F)
    2.14 to 2.58 kΩ
    a1-1 - a1-2
    20°C (68°F)
    1.71 to 2.05 kΩ
    a1-1 - a1-2
    25°C (77°F)
    1.38 to 1.64 kΩ
    a1-1 - a1-2
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Hold the sensor only by its connector. Touching the sensor may change the resistance value.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    Text in Illustration 
    *a
    Component without harness connected
    (Evaporator Temperature Sensor (No. 1 Cooler Thermistor))
    *b
    Sensing Portion
    *c
    Resistance (kΩ)
    *d
    Allowable Range
    *e
    Temperature (°C (°F))



NG
REPLACE EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR) (Click here)
OK


3.INSPECT AIR CONDITIONING HARNESS ASSEMBLY
E161765E23
  1. Remove the air conditioning harness assembly (Click here).



    E124472E50
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    z1-6 (TEA) - a1-2
    Always
    Below 1 Ω
    z1-5 (SGA) - a1-1
    Always
    Below 1 Ω
    z1-6 (TEA) - Body ground
    Always
    10 kΩ or higher
    z1-5 (SGA) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Air Conditioning Amplifier Assembly)
    *b
    Front view of wire harness connector
    (to Evaporator Temperature Sensor (No. 1 Cooler Thermistor))



NG
REPLACE AIR CONDITIONING HARNESS ASSEMBLY (Click here)
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)