DTC    P0778    Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)

for Preparation Click here


DESCRIPTION

Shifting from 1st to O/D is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1 and SL2 which is controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated smoothly (Fail safe function).

DTC No.
DTC Detection Condition
Trouble Area
P0778
ECM checks for an open or short circuit in shift solenoid valves SL2 (1-trip detection logic)
Hybrid IC for solenoid indicates fail.
  1. Open or short in shift solenoid valve SL2 circuit
  2. Shift solenoid valve SL2
  3. ECM

MONITOR DESCRIPTION

The ECM commands gear shifts by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid valves "ON/OFF" (In case of an open or short circuit, the ECM stops sending current to the circuit.)
(Click here).

WIRING DIAGRAM


C253235E06


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SL2)


    C155864E76
  1. Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    4 (SL2+) - 9 (SL2-)
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    OK:
    Standard Resistance (Check for short):  
    Tester Connection
    Condition
    Specified Condition
    4 (SL2+) - Body ground
    Always
    10 kΩ or higher
    9 (SL2-) - Body ground
    Always
    ↑

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Wire)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    A191204E88
  1. Connect the transmission wire connector to the transaxle.

  1. Disconnect the connector from the ECM.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E83-58 (SL2+) - E83-59 (SL2-)
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    OK:
    Standard Resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    E83-58 (SL2+) - Body ground
    Always
    10 kΩ or higher
    E83-59 (SL2-) - Body ground
    Always

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE SL2


    D025466E50
  1. Remove the shift solenoid valve SL2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.

    Text in Illustration 
    *1
    Shift Solenoid Valve SL2



NG
REPLACE SHIFT SOLENOID VALVE SL2 (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)