Home › Drivetrain · U660E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

AUTOMATIC TRANSAXLE SYSTEM > ECU Power Source Circuit

for Preparation Click here


DESCRIPTION

When the engine switch is turned to ON, voltage from the ECM's MREL terminal is applied to the EFI MAIN relay. This causes the contacts of the EFI MAIN relay to close, which supplies power to terminal +B of the TCM.

WIRING DIAGRAM


C240516E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.CHECK HARNESS AND CONNECTOR (TCM - BODY GROUND)


    C189544E61
  1. Disconnect the TCM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E7-8 (E1) - Body ground
    Always
    Below 1 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to TCM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.INSPECT ECU TERMINAL VOLTAGE (+B TERMINAL)


    C189544E62
  1. Disconnect the TCM connector.

  1. Turn the engine switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    E7-18 (+B) - Body ground
    Engine switch on (IG)
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to TCM)



NG
Go to step 3
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

3.CHECK HARNESS AND CONNECTOR (TCM - NO. 1 INTEGRATION RELAY)
  1. Remove the No. 1 integration relay from the engine room relay block and junction block assembly.

  1. Disconnect the No. 1 integration relay connector.

  1. Disconnect the TCM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    E7-18 (+B) - 1A-4
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    E7-18 (+B) or 1A-4 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

GO TO ECM POWER SOURCE CIRCUIT (ENGINE CONTROL SYSTEM / SFI SYSTEM) (Click here)