DTC P0660 Intake Manifold Tuning Valve Control Circuit / Open (Bank 1) |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0660 | The following conditions are met simultaneously for 0.5 seconds or more (2 trip detection logic):
|
|

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE VSV FOR INTAKE CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the tester on.
Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for Intake Control.
Check if operating noise can be heard when operating the intake air control valve assembly using the tester.
|
| ||||
| OK | ||
| ||
| 2.INSPECT INTAKE AIR SURGE TANK ASSEMBLY (INTAKE AIR CONTROL VALVE ASSEMBLY OPERATION) |
Inspect the intake air surge tank assembly (intake air control valve assembly) (Click here).
|
| ||||
| OK | |
| 3.CHECK TERMINAL VOLTAGE (POWER SOURCE OF INTAKE AIR CONTROL VALVE ASSEMBLY) |
![]() |
Disconnect the intake air control valve assembly connector.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E46-2 - Body ground | Engine switch on (IG) | 11 to 14 V |
| *a | Front view of wire harness connector (to Intake Air Control Valve Assembly) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (INTAKE AIR CONTROL VALVE ASSEMBLY - ECM) |
Disconnect the intake air control valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E46-1 - E26-47 (ACIS) | Always | Below 1 Ω |
| E46-1 or E26-47 (ACIS) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (INTAKE AIR CONTROL VALVE ASSEMBLY - NO. 1 INTEGRATION RELAY) |
Disconnect the intake air control valve assembly connector.
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E46-2 - 1A-8 | Always | Below 1 Ω |
| E46-2 or 1A-8 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||