POWER DOOR LOCK CONTROL SYSTEM > All Doors LOCK/UNLOCK Functions do not Operate Via Door Control Switch or Door Key Cylinder |

| 1.CHECK DOOR LOCK OPERATION |
Check door lock operation (Click here).
| Result | Proceed to |
| All doors cannot be locked through door control switch (power window regulator switch assembly) | A |
| All doors cannot be locked through door key cylinder | B |
|
| ||||
| A | |
| 2.READ VALUE USING TECHSTREAM (DOOR CONTROL SWITCH (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY)) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Door Lock SW-Lock | Door control switch (power window regulator master switch assembly) or door control switch assembly lock signal/ON or OFF | ON: Lock side of door control switch (power window regulator master switch assembly) or door control switch assembly pushed OFF: Lock side of door control switch (power window regulator master switch assembly) and door control switch assembly not pushed | - |
| Door Lock SW-Unlock | Door control switch (power window regulator master switch assembly) or door control switch assembly unlock signal/ON or OFF | ON: Unlock side of door control switch (power window regulator master switch assembly) or door control switch assembly pushed OFF: Unlock side of door control switch (power window regulator master switch assembly) and door control switch assembly not pushed | - |
|
| ||||
| OK | ||
| ||
| 3.INSPECT DOOR CONTROL SWITCH (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY) |
![]() |
Remove the door control switch (power window regulator master switch assembly) (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 (L) - 1 (E) | Lock switch pushed | Below 1 Ω |
| 2 (L) - 1 (E) | off | 10 kΩ or higher |
| 9 (UL) - 1 (E) | Unlock switch pushed | Below 1 Ω |
| 9 (UL) - 1 (E) | off | 10 kΩ or higher |
| *a | Component without harness connected (Door Control Switch (Power Window Regulator Master Switch Assembly)) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)) |
Disconnect the I13 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| K11-2 (L) - I13-9 (L1) | Always | Below 1 Ω |
| K11-9 (UL) - I13-10 (UL1) | Always | Below 1 Ω |
| K11-1 (E) - Body ground | Always | Below 1 Ω |
| K11-2 (L) - Body ground | Always | 10 kΩ or higher |
| K11-9 (UL) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK DOOR LOCK OPERATION (DOOR KEY CYLINDER) |
Proceed to the next step according to the symptom if all the doors cannot be locked/unlocked at once.
| Result | Proceed to |
| All doors cannot be locked/unlocked at once by using door key cylinder on driver door. | A |
| All doors cannot be locked/unlocked at once by using door key cylinder on front passenger door.* | B |
| All doors cannot be locked/unlocked at once by using both driver door and front passenger door key cylinder*. | C |
|
| ||||
|
| ||||
| A | |
| 6.READ VALUE USING TECHSTREAM (DOOR KEY-LINKED LOCK AND UNLOCK SWITCH) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Door Key SW-Lock | Driver door and front passenger door* key-linked lock/unlock switch lock signal/ON or OFF | ON: Driver door or front passenger door* key cylinder turned to lock position OFF: Driver door and front passenger door* key cylinder not turned to lock position | - |
| D Door Key SW-UL | Driver door key-linked lock/unlock switch unlock signal/ON or OFF | ON: Driver door key cylinder turned to unlock position OFF: Driver door key cylinder not turned to unlock position | - |
|
| ||||
| OK | ||
| ||
| 7.INSPECT FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH |
![]() |
Remove the front door lock with motor assembly LH (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 9 (L) - 7 (E) | Held to lock side | Below 1 Ω |
| 9 (L) - 7 (E) | Neutral or held to unlock side | 10 kΩ or higher |
| 10 (UL) - 7 (E) | Held to unlock side | Below 1 Ω |
| 10 (UL) - 7 (E) | Neutral or held to lock side | 10 kΩ or higher |
| *a | Component without harness connected (Front Door Lock with Motor Assembly LH) |
| *b | Lock |
| *c | Unlock |
|
| ||||
| OK | |
| 8.CHECK HARNESS AND CONNECTOR (FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)) |
Disconnect the I13 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| K1-9 (L) - I13-11 (L2) | Always | Below 1 Ω |
| K1-10 (UL) - I13-24 (UL3) | Always | Below 1 Ω |
| K1-7 (E) - Body ground | Always | Below 1 Ω |
| I13-11 (L2) - Body ground | Always | 10 kΩ or higher |
| I13-24 (UL3) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 9.READ VALUE USING TECHSTREAM (DOOR KEY-LINKED LOCK AND UNLOCK SWITCH) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Door Key SW-Lock | Driver door and front passenger door* key-linked lock/unlock switch lock signal/ON or OFF | ON: Driver door or front passenger door* key cylinder turned to lock position OFF: Driver door and front passenger door* key cylinder not turned to lock position | - |
| Door Key SW-Unlock | Passenger door key-linked lock/unlock switch unlock signal/ON or OFF | ON: Passenger door key cylinder turned to unlock position OFF: Passenger door key cylinder not turned to unlock position | - |
|
| ||||
| OK | ||
| ||
| 10.INSPECT FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH |
![]() |
Remove the front door lock with motor assembly RH (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 6 (L) - 8 (E) | Held to lock side | Below 1 Ω |
| 6 (L) - 8 (E) | Neutral or held to unlock side | 10 kΩ or higher |
| 5 (UL) - 8 (E) | Held to unlock side | Below 1 Ω |
| 5 (UL) - 8 (E) | Neutral or held to lock side | 10 kΩ or higher |
| *a | Component without harness connected (Front Door Lock with Motor Assembly RH) |
| *b | Lock |
| *c | Unlock |
|
| ||||
| OK | |
| 11.CHECK HARNESS AND CONNECTOR (FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)) |
Disconnect the I13 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J1-6 (L) - I13-11 (L2) | Always | Below 1 Ω |
| J1-5 (UL) - I13-12 (UL2) | Always | Below 1 Ω |
| J1-8 (E) - Body ground | Always | Below 1 Ω |
| F13-11 (L2) - Body ground | Always | 10 kΩ or higher |
| F13-12 (UL2) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||