BLIND SPOT MONITOR SENSOR > INSTALLATION |
| 1. INSTALL BLIND SPOT MONITOR COVER |
Engage the claw.
Install the blind spot monitor cover with the 2 nuts.
| 2. INSTALL BLIND SPOT MONITOR SENSOR |
![]() |
Connect the connector.
| *A | for RH Side: |
| *B | for LH Side: |
| *1 | Identification Mark |
Install the blind spot monitor sensor with the 3 nuts.
for LH Side:
Engage the 2 clamps.
for RH Side:
Engage the clamp.
| 3. INSTALL REAR BUMPER ASSEMBLY |
| 4. PERFORM BLIND SPOT MONITOR BEAM AXIS INSPECTION |
Refer to operation check (Click here).
| 5. PERFORM DIAGNOSTIC SYSTEM CHECK |