SFI SYSTEM > Air Intake Control Circuit |


| 1.PERFORM ACTIVE TEST USING TECHSTREAM (ACTIVATE THE VSV FOR AICS) |
![]() |
Disconnect the vacuum hose (Port F) from the vacuum switching valve (for air intake control valve).
Connect the Techstream to the DLC3.
Start the engine.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for AICS.
Check the operation of the vacuum switching valve (for air intake control valve) when the vacuum switching valve (for air intake control valve) is operated using the Techstream.
| Techstream Operation | Specified Condition |
| ON | Air from port E flows out through port F |
| OFF | Air from port E flows out through the air filter |
| *1 | Air |
| *2 | Port E |
| *3 | Port F |
| *4 | Air Filter |
| *a | Vacuum Switching Valve is On |
| *b | Vacuum Switching Valve is Off |
|
| ||||
| OK | ||
| ||
| 2.INSPECT VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE) |
Inspect the vacuum switching valve for air intake control valve (Click here).
|
| ||||
| OK | |
| 3.CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE)) |
![]() |
Disconnect the vacuum switching valve (for air intake control valve) connector.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A9-1 - Body ground | Engine switch on (IG) | 11 to 14 V |
| *a | Front view of wire harness connector (to Vacuum Switching Valve (for Air Intake Control Valve)) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE) - ECM) |
Disconnect the vacuum switching valve (for air intake control valve) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A9-2 - E26-46 (AICV) | Always | Below 1 Ω |
| A9-2 or E26-46 (AICV) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 5.INSPECT AIR CLEANER CAP SUB-ASSEMBLY (VACUUM SURGE TANK) |
Inspect the vacuum surge tank (Click here).
|
| ||||
| OK | |
| 6.CHECK VACUUM HOSES (VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE) - AIR CLEANER CAP - AIR INTAKE CONTROL VALVE) |
Check the vacuum hoses between vacuum switching valve (for air intake control valve), air cleaner cap sub-assembly and air intake control valve (Click here).
|
| ||||
| OK | ||
| ||
| 7.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE)) |
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Disconnect the vacuum switching valve (for air intake control valve) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1C-3 - A9-1 | Always | Below 1 Ω |
| 1C-3 or A9-1 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||