Home › Engine / Hybrid System · 2GR-FE › ENGINE CONTROL › SFI SYSTEM

SFI SYSTEM > Air Intake Control Circuit

for Preparation Click here


DESCRIPTION

The air cleaner is equipped with 2 inlets, one of which is opened or closed by the air intake control valve. This system reduces intake noise and increases engine power at low-to-high engine speed ranges.
When the engine is operating in the low-to-mid speed range, this control operates the air intake control valve to close one of the air cleaner inlets. When the engine speed is higher than 3600 rpm and the opening angle of the throttle valve is more than 60°, the ECM activates the vacuum switching valve (for air intake control valve) and opens the air intake control valve.

A212427E03


WIRING DIAGRAM


A266399E02


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.PERFORM ACTIVE TEST USING TECHSTREAM (ACTIVATE THE VSV FOR AICS)


    A204525E03
  1. Disconnect the vacuum hose (Port F) from the vacuum switching valve (for air intake control valve).

  1. Connect the Techstream to the DLC3.

  1. Start the engine.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for AICS.

  1. Check the operation of the vacuum switching valve (for air intake control valve) when the vacuum switching valve (for air intake control valve) is operated using the Techstream.

    Standard:
    Techstream Operation
    Specified Condition
    ON
    Air from port E flows out through port F
    OFF
    Air from port E flows out through the air filter

    Text in Illustration 
    *1
    Air
    *2
    Port E
    *3
    Port F
    *4
    Air Filter
    *a
    Vacuum Switching Valve is On
    *b
    Vacuum Switching Valve is Off



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE)
  1. Inspect the vacuum switching valve for air intake control valve (Click here).



NG
REPLACE VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE) (Click here)
OK


3.CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE))


    A203087E32
  1. Disconnect the vacuum switching valve (for air intake control valve) connector.

  1. Turn the engine switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A9-1 - Body ground
    Engine switch on (IG)
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Vacuum Switching Valve (for Air Intake Control Valve))



NG
Go to step 7
OK


4.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE) - ECM)
  1. Disconnect the vacuum switching valve (for air intake control valve) connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    A9-2 - E26-46 (AICV)
    Always
    Below 1 Ω
    A9-2 or E26-46 (AICV) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.INSPECT AIR CLEANER CAP SUB-ASSEMBLY (VACUUM SURGE TANK)
  1. Inspect the vacuum surge tank (Click here).



NG
REPAIR OR REPLACE AIR CLEANER CAP SUB-ASSEMBLY
OK


6.CHECK VACUUM HOSES (VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE) - AIR CLEANER CAP - AIR INTAKE CONTROL VALVE)
  1. Check the vacuum hoses between vacuum switching valve (for air intake control valve), air cleaner cap sub-assembly and air intake control valve (Click here).



NG
REPAIR OR REPLACE VACUUM HOSE
OK

REPLACE ECM (Click here)  

7.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - VACUUM SWITCHING VALVE (FOR AIR INTAKE CONTROL VALVE))
  1. Remove the No. 1 integration relay from the engine room relay block and junction block assembly.

  1. Disconnect the vacuum switching valve (for air intake control valve) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    1C-3 - A9-1
    Always
    Below 1 Ω
    1C-3 or A9-1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

GO TO ECM POWER SOURCE CIRCUIT (Click here)