SFI SYSTEM > ACIS Control Circuit |


| 1.PERFORM ACTIVE TEST USING TECHSTREAM (OPERATE VACUUM SWITCHING VALVE ASSEMBLY FOR ACIS) |
![]() |
Disconnect the vacuum hose from port F of the vacuum switching valve assembly (for acoustic control induction system).
Connect the Techstream to the DLC3.
Start the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Active the VSV for Intake Control.
Operate the vacuum switching valve assembly for acoustic control induction system.
Check the vacuum switching valve assembly air flow when switching the vacuum switching valve assembly.
| Test Condition | Specified Condition |
| Vacuum switching valve assembly is ON | Air from port E flows out through port F |
| Vacuum switching valve assembly is OFF | Air from port E flows out through air filter |
| *1 | Air |
| *2 | Port F |
| *3 | Port E |
| *4 | Air Filter |
| *a | Vacuum Switching Valve Assembly is ON |
| *b | Vacuum Switching Valve Assembly is OFF |
|
| ||||
| OK | |
| 2.CHECK VACUUM HOSES (VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) - INTAKE AIR CONTROL VALVE, INTAKE MANIFOLD) |
Check the vacuum hoses (Click here).
|
| ||||
| OK | |
| 3.INSPECT INTAKE MANIFOLD (INTAKE AIR CONTROL VALVE FOR ACIS) |
Inspect the intake air control valve (for acoustic control induction system) .
|
| ||||
| OK | ||
| ||
| 4.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) |
Inspect the vacuum switching valve assembly (for acoustic control induction system) (Click here).
|
| ||||
| OK | |
| 5.CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE ASSEMBLY) |
![]() |
Disconnect the vacuum switching valve assembly connector.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E45-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Vacuum Switching Valve Assembly (for ACIS)) |
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE ASSEMBLY - ECM) |
Disconnect the vacuum switching valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E45-1 (ACIS) - E26-69 (ACIS) | Always | Below 1 Ω |
| E45-1 (ACIS) or E26-69 (ACIS) - Body ground | Always | 10 kΩor higher |
|
| ||||
| OK | ||
| ||
| 7.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - VACUUM SWITCHING VALVE ASSEMBLY) |
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Disconnect the vacuum switching valve assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1A-8 - E45-2 (+B) | Always | Below 1 Ω |
| 1A-8 or E45-2 (+B) - Body ground | Always | 10 kΩor higher |
|
| ||||
| OK | ||
| ||