PARKING ASSIST MONITOR SYSTEM > Guide Lines and Buttons are not Displayed for All Display Modes |

| 1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the engine switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Luggage Courtesy SW | Luggage compartment door courtesy switch signal/ON or OFF | ON: Luggage compartment door open OFF: Luggage compartment door closed | - |
|
| ||||
| OK | ||
| ||
| 2.INSPECT LUGGAGE COMPARTMENT DOOR LOCK ASSEMBLY |
![]() |
Check operation of the door courtesy switch.
Measure the resistance according to the value(s) in the table below.
| Measurement Condition | Switch Condition | Specified Condition |
| 2 (E) - 3 (D+) | Close (Lock) | 10 kΩ or higher |
| 2 (E) - 3 (D+) | Open (Unlock) | Below 1 Ω |
| *a | Component without harness connected (Luggage Compartment Door Lock Assembly) |
| *b | Close (Lock) |
| *c | Open (Unlock) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (LUGGAGE COMPARTMENT DOOR LOCK ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) |
Disconnect the T3 luggage compartment door lock assembly connector.
Disconnect the 3C instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| T3-3 (D+) - 3C-9 | Always | Below 1 Ω |
| T3-3 (D+) - Body ground | Always | 10 kΩ or higher |
| T3-2 (E) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly (Click here).
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.

| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
| Tester Connection | Condition | Specified Condition |
| 3C-9 - MB-4 (LGCY) | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||