89667E
1.INSTALL NO. 1 ECM BRACKET
Install the No. 1 ECM bracket with the nut.
Connect the 2 wire harness clamps.
Install the nut.
89661
2.INSTALL ECM
Install the No. 2 ECM bracket to the ECM with the 2 screws.
Temporarily install the screw (B).
Install the ECM with the nut.
Install the screw (A).
Tighten the screw (B).
Connect the 2 ECM connectors and lower the 2 levers.
When connecting the connectors, make sure that dirt, water or other foreign matter does not become stuck between the connecting parts.
Make sure that the 2 levers are securely locked.
28800
3.INSTALL BATTERY
53295E
4.INSTALL COOL AIR INTAKE DUCT SEAL
5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
When disconnecting the cable from the negative (-) battery terminal, some systems need to be initialized after the cable is reconnected.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
6.PERFORM INITIALIZATION