The solar sensor (automatic light control sensor) is installed on the upper side of the instrument panel. It detects sunlight to control air conditioning AUTO mode. The output voltage from the solar sensor (automatic light control sensor) varies in accordance with the amount of sunlight. When the sunlight increases, the output voltage increases. As the sunlight decreases, the output voltage decreases. The air conditioning amplifier assembly detects changes in the output voltage from the solar sensor (automatic light control sensor).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B14A2 | Driver Side Solar Sensor Short Circuit | Short in driver side solar sensor (automatic light control sensor) circuit | ·
Solar sensor (automatic light control sensor) ·
Harness or connector between automatic light control sensor (solar sensor) and air conditioning amplifier assembly ·
Harness or connector between automatic light control sensor (solar sensor) and main body ECU (multiplex network body ECU) ·
Main body ECU (multiplex network body ECU) ·
Air conditioning amplifier assembly |
Memorized
(4 sec. or more)*1 |
*1: The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the brackets.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Solar Sensor (D Side) | Driver side automatic light control sensor (solar sensor) | Min.: 0
Max.: 255 |
Driver side solar sensor (automatic light control sensor) value increases as brightness increases | - |
| Tester Display |
|---|
| Solar Sensor (D Side) |
The display is as specified in the Normal Condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>PROBLEM SYMPTOMS TABLE
C
| *a | Front view of wire harness connector
(to Solar Sensor (Automatic Light Control Sensor)) |
Disconnect the I61 solar sensor (automatic light control sensor) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I61-6 (CLTB) - I61-3 (CLTE) | Ignition switch off | Below 1 V |
| I61-6 (CLTB) - I61-3 (CLTE) | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I77 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I77-33 (TSD) - I61-2 (TSR)*1 | Always | Below 1 Ω |
| I77-33 (TSD) - I61-1 (TSL)*2 | Always | Below 1 Ω |
| I77-33 (TSD) - Body ground | Always | 10 kΩ or higher |
*1: for RHD
*2: for LHD
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *A | for RHD |
| *B | for LHD |
| *a | Component with harness connected
(Solar Sensor (Automatic Light Control Sensor)) |
Remove the solar sensor (automatic light control sensor).
Click hereVehicle Interior>HEATING / AIR CONDITIONING>SOLAR SENSOR>REMOVAL
Reconnect the I61 solar sensor (automatic light control sensor).
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I61-2 (TSR) - I61-3 (CLTE)*1 | Sensor is subjected to electric light | 0.8 to 4.3 V |
| I61-2 (TSR) - I61-3 (CLTE)*1 | Sensor is covered with a cloth | Below 0.8 V |
| I61-1 (TSL) - I61-3 (CLTE)*2 | Sensor is subjected to electric light | 0.8 to 4.3 V |
| I61-1 (TSL) - I61-3 (CLTE)*2 | Sensor is covered with a cloth | Below 0.8 V |
*1: for RHD
*2: for LHD
The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the negative (-) lead to terminal 2 and the positive (+) lead to terminal 6 of the solar sensor (automatic light control sensor).
Do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor (automatic light control sensor).
As the inspection light is moved away from the sensor, the voltage decreases.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I13 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I13-20 (CLTB) - I61-6 (CLTB) | Always | Blow 1 Ω |
| I13-22 (CLTE) - I61-3 (CLTE) | Always | Blow 1 Ω |
| I13-20 (CLTB) - Body ground | Always | 10 kΩ or higher |
| I13-22 (CLTE) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG