The headlight leveling ECU assembly actuates the headlight leveling motors according to vehicle conditions.
Connect the intelligent tester to the DLC3.
Start the engine.
Turn the intelligent tester on.
Enter the following menus: Body / HL AutoLeveling / Active Test.
Perform the Active Test according to the display on the intelligent tester.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Drive The Leveling Motor | Headlight leveling motor operation | Up/Down/Stop | Perform the Active Test with the engine running |
| Tester Display |
|---|
| Drive The Leveling Motor |
Headlight leveling motors operate normally.
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Exterior>LIGHTING (EXT)>AUTOMATIC HEADLIGHT BEAM LEVEL CONTROL SYSTEM>PROBLEM SYMPTOMS TABLE
NG
Disconnect the A78 headlight leveling ECU assembly connector.
Disconnect the A76 or A81 headlight leveling motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A78-18 (LHT) - A76-2 (LH T) | Always | Below 1 Ω |
| A78-11 (LH+) - A76-3 (LHIG) | Always | Below 1 Ω |
| A78-24 (LH-) - A76-1 (LH E) | Always | Below 1 Ω |
| A78-18 (LHT) - Body ground | Always | 10 kΩ or higher |
| A78-11 (LH+) - Body ground | Always | 10 kΩ or higher |
| A78-24 (LH-) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A78-17 (RHT) - A81-2 (RH T) | Always | Below 1 Ω |
| A78-10 (RH+) - A81-3 (RHIG) | Always | Below 1 Ω |
| A78-23 (RH-) - A81-1 (RH E) | Always | Below 1 Ω |
| A78-17 (RHT) - Body ground | Always | 10 kΩ or higher |
| A78-10 (RH+) - Body ground | Always | 10 kΩ or higher |
| A78-23 (RH-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the headlight leveling motor with a new or known good one.
Click hereVehicle Exterior>LIGHTING (EXT)>HEADLIGHT ASSEMBLY>REMOVAL
Perform the Active Test of the leveling motors.
Headlight leveling motors operate normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG