Refer to the description for DTC P0A37-260 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A37-260).
After confirming that DTC P0A38-257 or P0A39-259 is output, use the intelligent tester to check "Motor Temp No2" in the power management control ECU Data List.
| Displayed Temperature | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit or short to +B |
| 215°C (419°F) | Short circuit or short to GND |
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A38-257 | Generator Temperature Sensor Circuit Low | Short to GND in the generator temperature sensor circuit | ·
Wire harness or connector ·
Power management control ECU ·
Hybrid vehicle transaxle assembly (Generator temperature sensor) |
Does not come on | Master Warning Light:
Comes on |
| P0A39-259 | Generator Temperature Sensor Circuit High | Open or short to +B in the generator temperature sensor circuit | ·
Wire harness or connector ·
Power management control ECU ·
Hybrid vehicle transaxle assembly (Generator temperature sensor) |
Does not come on | Master Warning Light:
Comes on |
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0340-886)
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.
| Tester Display |
|---|
| Motor Temp No2 |
Read the Data List.
| Result | Proceed to |
|---|---|
| -40°C (-40°F) | A |
| 215°C (419°F) | B |
| Same as actual temperature | C |
Turn the power switch off.
A
B
C
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>CHECK FOR INTERMITTENT PROBLEMS)
Disconnect the generator temperature sensor connector.
| *a | Front view of wire harness connector
(to Generator Temperature Sensor) |
Connect terminals 4 (GMT) and 8 (GMTG) of vehicle side connector E13 of the generator temperature sensor.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.
| Tester Display |
|---|
| Motor Temp No2 |
Read the Data List.
| Tester Display | Condition | Specified Condition |
| Motor Temp No2NG | Terminals GMT and GMTG connected.
Power switch on (IG) |
215°C (419°F) |
The generator temperature sensor is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.
Turn the power switch off.
Connect the generator temperature sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the generator temperature sensor connector.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.
Read the Data List.
| Tester Display | Condition | Specified Condition |
| Motor Temp No2 | Power switch on (IG) | -40°C (-40°F) |
The generator temperature sensor is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.
Turn the power switch off.
Connect the generator temperature sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Power Management Control ECU) |
Connect terminals 26 (GMT) and 27 (GMTG) of connector A38 of the power management control ECU.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.
Read the Data List.
| Tester Display | Condition | Specified Condition |
| Motor Temp No2NG | Terminals GMT and GMTG connected.
Power switch on (IG) |
215°C (419°F) |
Turn the power switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the generator temperature sensor connector.
Disconnect connector A38 from the power management control ECU.
Measure the resistance according to the value(s) in the table below.
| *a | Front view or wire harness connector
(to Generator Temperature Sensor) |
*b | Rear view of wire harness connector
(to Power Management Control ECU) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E13-4 (GMT) - A38-26 (GMT) | Power switch off | Below 1 Ω |
| E13-8 (GMTG) - A38-27 (GMTG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E13-4 (GMT) or A38-26 (GMT) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| E13-8 (GMTG) or A38-27 (GMTG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Connect the power management control ECU connector.
Connect the generator temperature sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG