Refer to the description for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).
This circuit uses the power management control ECU to monitor the system main relays and stops the system if a malfunction is detected in the relays, because it may be impossible to shut off the high-voltage system if any of the relays becomes stuck.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0AA1-233 | Hybrid Battery Positive Contactor Circuit Stuck Closed | SMRP, SMRB and SMRG on the HV battery positive and negative sides are stuck closed. | ·
Hybrid battery junction block assembly ·
Inverter with converter assembly |
Does not come on | Master Warning Light:
Comes on |
Refer to the wiring diagram for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).
When performing P0AA1-233 troubleshooting, use either a tool wrapped with vinyl insulation tape or a insulated tool. (It is extremely dangerous when a high-voltage charge passes through a non-insulated tool causing a short.)
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
If P0AA1-233 is stored, the hybrid system cannot be turned on.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0AA1-233 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A-151, 155, 156, 200, 658, 659, 791, 792, 793 | Generator Control Module |
| P0A1B-163, 164, 168, 193, 511, 512, 661, 786, 794, 795, 796 | Drive Motor "A" Control Module |
| P0A1D-148 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-266, 267, 586 | Drive Motor "A" Inverter Performance |
| P0A94-442 | DC / DC Converter Performance |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0AE7-224 | Hybrid Battery Precharge Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P2511-149 | ECM / PCM Power Relay Sensor Circuit Intermittent |
| P3004-132 | High Voltage Power Resource |
| P324E-788 | MG-ECU Power Relay Intermittent Circuit |
| U0110 (all INF codes)*1 | Lost Communication with Drive Motor Control Module "A" |
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0AA1-233 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
Turn the power switch off.
A
B
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data of DTC P0AA1-233.
| Result | Proceed to |
|---|---|
| VH-Voltage after Boosting minus VL-Voltage before Boosting is 100 V or less. | A |
| The preceding condition is not satisfied. | B |
Turn the power switch off.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly (Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Q2-1 (CBI) - A-1 (+) | Power switch off | 10 kΩ or higher |
If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.
If the result of reading the freeze frame data is A, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Q3-1 (CEI) - q1-1 (-) | Power switch off | 10 kΩ or higher |
If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.
If the result of reading the freeze frame data is A, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
If the resistance is between 28.5 and 31.5 Ω, it can be determined that SMRP is stuck closed.
Install the No. 1 hybrid battery shield sub-assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG