This DTC indicates that the power management control ECU monitors the +B power source voltage to detect an instantaneous interruption.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P2511-149 | HV CPU Power Relay Sense Circuit Intermittent No Continuity | When the power switch is on (READY), the power management control ECU is reset. | ·
Wire harness or connector ·
Power management control ECU |
Does not come on | Master Warning Light:
Comes on |
Refer to the wiring diagram for DTC P3110-223 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P3110-223).
Confirm whether the auxiliary battery terminals have been disconnected recently.
| Result | Proceed to |
|---|---|
| Terminals have been disconnected. | A |
| Terminals have not been disconnected. | B |
A
B
Turn the power switch on (READY) from off.
Confirm that the master warning light illuminates.
| Result | Proceed to |
|---|---|
| Master warning light illuminates. | A |
| Master warning light does not illuminates. | B |
DTC P2511-149 may be stored after disconnecting and reconnecting the auxiliary battery terminals. If this happens, the DTC will not be output if the power switch is turned off and then on (READY) again. In this case, clear DTCs to complete the inspection.
Turn the power switch off.
A
B
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read and record the DTCs and freeze frame data.
Clear the DTCs and freeze frame data.
Turn the power switch off.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P2511-149 is output again. | A |
| DTCs other than P2511-149 are also output. | B |
Turn the power switch off.
A
B
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Check the connection of the auxiliary battery terminal.
The terminal is connected securely and there is no contact problem.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0340-886)
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGCT relay from the No. 2 engine room relay block.
Disconnect connectors A38 and A39 from power management control ECU.
| *1 | No. 2 Engine Room Relay Block | *2 | IGCT Relay |
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
- | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-5 (+B1) - 5 (IGCT relay) | Power switch off | Below 1 Ω |
| A38-2 (+B2) - 5 (IGCT relay) | Power switch off | Below 1 Ω |
Install the IGCT relay.
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for intermittent problems (Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>CHECK FOR INTERMITTENT PROBLEMS).
Check the connection and terminal contact pressure of connectors and wire harnesses between the power management control ECU and the No. 2 engine room relay block.
When the power switch is on (READY), jiggle the connectors and wire harnesses between the power management control ECU and the No. 2 engine room relay block.
| Result | Proceed to |
|---|---|
| Problem symptom does not recur. | A |
| Problem symptom recurs. | B |
A
B