The power management control ECU detects a wiring malfunction in the serial communication line between it and the compressor with motor assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P3108-536 | Lost Communication with A/C System Control Module | A/C inverter malfunction | ·
Wire harness or connector ·
Compressor with motor assembly ·
Power management control ECU |
Does not come on | Master Warning Light:
Does not come on |
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0340-886)
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the connection of connector E65 of the compressor with motor assembly.
The connector is connected securely and there are no contact problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector E65 from the compressor with motor assembly.
| *a | Front view of wire harness connector
(to Compressor with Motor Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E65-5 (GND) - Body ground | Power switch off | Below 1 Ω |
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E65-6 (IG1) - E65-5 (GND) | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the compressor with motor assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Connect the compressor with motor assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the intelligent tester to the DLC3.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P3108-536 is output. | A |
| P3108-536 is not output. | B |
Turn the power switch off.
A
B
Disconnect connector A38 from the power management control ECU.
Disconnect connector E65 from the compressor with motor assembly.
Turn the power switch on (IG).
| *1 | Rear view of wire harness connector
(to Power Management Control ECU) |
| *2 | Front view of wire harness connector
(to Compressor with Motor Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-19 (CLK) - Body ground | Power switch on (IG) | Below 1 V |
| A38-30 (ETI) - Body ground | Power switch on (IG) | Below 1 V |
| A38-31 (ITE) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the power management control ECU connector and the compressor with motor assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-19 (CLK) - E65-1 (CLK) | Power switch off | Below 1 Ω |
| A38-30 (ETI) - E65-3 (DOUT) | Power switch off | Below 1 Ω |
| A38-31 (ITE) - E65-2 (DIN) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-19 (CLK) or E65-1 (CLK) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A38-30 (ETI) or E65-3 (DOUT) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A38-31 (ITE) or E65-2 (DIN) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Connect the compressor with motor assembly connector.
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector E65 from the compressor with motor assembly.
| *a | Front view of wire harness connector
(to Compressor with Motor Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E65-3 (DOUT) - Body ground | Power switch off | 10 kΩ or higher |
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E65-1 (CLK) - Body ground | Power switch on (IG) | 11 to 14 V |
| E65-2 (DIN) - Body ground | Power switch on (IG) | 11 to 14 V |
| E65-3 (DOUT) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the compressor with motor assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Connect the compressor with motor assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector A38 from the power management control ECU.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-19 (CLK) - Body ground | Power switch off | 10 kΩ or higher |
| A38-31 (ITE) - Body ground | Power switch off | 10 kΩ or higher |
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-30 (ETI) - Body ground | Power switch on (IG) | 11 to 14 V |
| A38-19 (CLK) - Body ground | Power switch on (IG) | Below 1 V |
| A38-31 (ITE) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector A38 from the power management control ECU.
Disconnect connector E65 from the compressor with motor assembly.
Turn the power switch on (IG).
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| *b | Front view of wire harness connector
(to Compressor with Motor Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-20 (STB) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-20 (STB) - E65-4 (STBI) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-20 (STB) or E65-4 (STBI) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Connect the compressor with motor assembly connector.
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector E65 from the compressor with motor assembly.
| *a | Front view of wire harness connector
(to Compressor with Motor Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E65-4 (STBI) - Body ground | Power switch off | 10 kΩ or higher |
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E65-4 (STBI) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the compressor with motor assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Connect the compressor with motor assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector A38 from the power management control ECU.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-20 (STB) - Body ground | Power switch off | 10 kΩ or higher |
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-20 (STB) - Body ground | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG