For a description of the inverter.
See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A78-266
The MG ECU located in the inverter with converter assembly controls MG2 based on commands from the power management control ECU. The MG ECU monitors communication data and detects malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| U0110-159 | Lost Communication with Drive Motor Control Module "A" | Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard) | ·
Wire harness or connector ·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Power management control ECU ·
INV fuse |
Does not come on | Master Warning Light:
Comes on |
| U0110-656 | Lost Communication with Drive Motor Control Module "A" | Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard) | ·
Wire harness or connector ·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Power management control ECU ·
INV fuse |
Does not come on | Master Warning Light:
Comes on |
| U0110-657 | Lost Communication with Drive Motor Control Module "A" | Error in reception from inverter with converter assembly (MG ECU) via serial communication (no reception) | ·
Wire harness or connector ·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Power management control ECU ·
INV fuse |
Does not come on | Master Warning Light:
Comes on |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
If any of the DTCs U0110-159, U0110-656, and U0110-657 was set due to incomplete engagement of the connectors, and if the system returns to normal when the power switch is turned on (IG) after clearing the DTCs, DTC P324E-788 will be set. Proceed to troubleshooting without considering DTC P324E-788.
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV Fuse |
Remove the INV fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV fuse terminals | Always | Below 1 Ω |
Install the INV fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A09-591
| Proceed to |
|---|
| NEXT |
NEXT
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| DTC U0110-159, 656 or 657 is output. | A |
| DTC U0110-159, 656 and 657 are not output. | B |
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A78-113
| Proceed to |
|---|
| A |
| B |
| C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A78-113
| Proceed to |
|---|
| A |
| B |
| C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A78-113
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A78-113
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A14 from the inverter with converter assembly.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A14-10 (GND1) - Body ground | Power switch off | Below 1 Ω |
| A14-11 (GND2) - Body ground | Power switch off | Below 1 Ω |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A14-30 (+B) - Body ground | Power switch on (IG) | 11 to 14 V |
| A14-31 (+B2) - Body ground | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Connect the inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect an oscilloscope between the power management control ECU terminals specified in the following table.
Turn the power switch on (IG).
| *a | Component with harness connected
(Power Management Control ECU) |
Measure the waveform.
| Item | Contents |
|---|---|
| Tester Connection | CH1: A39-21 (CLK+) - I3-6 (E1)
CH2: A39-20 (CLK-) - I3-6 (E1) |
| Equipment Setting | 1V/DIV., 1μs/DIV. |
| Condition | Power switch on (IG) |
| Result | Proceed to |
|---|---|
| The waveform appears as shown in the illustration. | A |
| The waveform differs from the one shown in the illustration. | B |
Inspect with the connector connected.
If pulses are generated, the shape of the waveform can be assumed to be normal.
The shape of the waveform may vary according to communication conditions.
Turn the power switch off.
A
B
Connect an oscilloscope between the power management control ECU terminals specified in the following table.
Turn the power switch on (IG).
| *a | Component with harness connected
(Power Management Control ECU) |
Measure the waveform.
| Item | Contents |
|---|---|
| Tester Connection | CH1: A39-33 (REQ+) - I3-6 (E1)
CH2: A39-32 (REQ-) - I3-6 (E1) |
| Equipment Setting | 1V/DIV., 1ms/DIV. |
| Condition | Power switch on (IG) |
| Result | Proceed to |
|---|---|
| The waveform appears as shown in the illustration. | A |
| The waveform differs from the one shown in the illustration. | B |
Inspect with the connector connected.
If pulses are generated, the shape of the waveform can be assumed to be normal.
The shape of the waveform may vary according to communication conditions.
Turn the power switch off.
A
B
Connect an oscilloscope between the power management control ECU terminals specified in the following table.
Turn the power switch on (IG).
| *a | Component with harness connected
(Power Management Control ECU) |
Measure the waveform.
| Item | Contents |
|---|---|
| Tester Connection | CH1: A39-30 (MTH+) - I3-6 (E1)
CH2: A39-29 (MTH-) - I3-6 (E1) |
| Equipment Setting | 1V/DIV,, 200μs/DIV, |
| Condition | Power switch on (IG) |
| Result | Proceed to |
|---|---|
| The waveform appears as shown in the illustration. | A |
| The waveform differs from the one shown in the illustration. | B |
Inspect with the connector connected.
If pulses are generated, the shape of the waveform can be assumed to be normal.
The shape of the waveform may vary according to communication conditions.
Turn the power switch off.
A
B
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV Fuse |
Replace the INV fuse.
Turn the power switch on (READY).
Check if there is an open circuit in the INV fuse in the No.2 engine room relay block.
There is no open circuit in the INV fuse.
If the fuse does not become open again after turning the power switch on (READY), it can be assumed that the previous fuse failed due to age.
Turn the power switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A39 from the power management control ECU.
Disconnect connector A14 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| *b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-21 (CLK+) - Body ground | Power switch on (IG) | Below 1 V |
| A39-20 (CLK-) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the power management control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-21 (CLK+) - A14-7(CLK+) | Power switch off | Below 1 Ω |
| A39-20 (CLK-) - A14-18 (CLK-) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-21 (CLK+) or A14-7 (CLK+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-20 (CLK-) or A14-18 (CLK-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector A39 from the power management control ECU.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-21 (CLK+) - A39-20 (CLK-) | Power switch off | 80 to 170 Ω |
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A39 from the power management control ECU.
Disconnect connector A14 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| *b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-33 (REQ+) - Body ground | Power switch on (IG) | Below 1 V |
| A39-32 (REQ-) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the power management control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-33 (REQ+) - A14-26 (REQ+) | Power switch off | Below 1 Ω |
| A39-32 (REQ-) - A14-37 (REQ-) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-33 (REQ+) or A14-26 (REQ+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-33 (REQ+) or A14-26 (REQ+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector A39 from the power management control ECU.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-33 (REQ+) - A39-32 (REQ-) | Power switch off | 80 to 170 Ω |
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A39 from the power management control ECU.
Disconnect connector A14 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| *b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-30 (MTH+) - Body ground | Power switch on (IG) | Below 1 V |
| A39-29 (MTH-) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the power management control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-30 (MTH+) - A14-8 (MTH+) | Power switch off | Below 1 Ω |
| A39-29 (MTH-) - A14-19 (MTH-) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-30 (MTH+) or A14-8(MTH+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A39-29 (MTH-) or A14-19 (MTH-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A14 from the inverter with converter assembly.
| *a | Component with harness connected
(Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-30 (MTH+) - A39-29 (MTH-) | Power switch off | 80 to 170 Ω |
Connect the power management control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV Fuse |
Remove the INV fuse from the No. 2 engine room relay block.
Disconnect connector A14 from the inverter with converter assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 2 Engine Room Relay Block | *2 | INV Fuse |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
- | - |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A14-30 (+B), A14-31 (+B2) or 2 (INV fuse terminal) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Connect the inverter with converter assembly connector.
Install the PCU fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>COMPONENTS
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT