Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074886 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A85-123  Hybrid Battery Pack Cooling Fan 1 Control Circuit High  


DESCRIPTION

Refer to the circuit description for DTC P0A84-123.

See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A84-123

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A85-123 Hybrid Battery Pack Cooling Fan 1 Control Circuit High When the speed calculated based on the battery cooling blower assembly frequency (FP) is out of the target control speed range (1 trip detection)
·

Battery cooling blower assembly

·

Battery smart unit


Does not come on Master Warning Light:
Comes on

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A84-123.

See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A84-123

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.NOTICE:



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

See pageGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK FOR DTCS (HV)

A

2.CHECK BATTERY SMART UNIT (FREQUENCY)

B

2.CHECK BATTERY SMART UNIT (FREQUENCY)

OK

REPLACE BATTERY COOLING BLOWER ASSEMBLY

NG