1.DRAIN COOLANT (for Inverter)
G92A0A
2.REMOVE INVERTER RESERVE TANK ASSEMBLY
Remove the 2 bolts and inverter reserve tank assembly.
G9040
3.REMOVE WATER PUMP WITH MOTOR ASSEMBLY
Disconnect the water hose.
Put pieces of cloth into the pipe and in the disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
Disconnect the connector.
Apply insulating tape to the connectors of the wire harness and inverter water pump assembly with motor to prevent the entry of coolant.
Remove the 3 bolts.
Disconnect the water hose.
Put pieces of cloth into the pipe and in the disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.