Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY
RM2040EQ _57 Power Source / Network _014720 POWER DISTRIBUTION _0075040 INTEGRATION RELAY A

POWER DISTRIBUTION  INTEGRATION RELAY  INSTALLATION  


PROCEDURE

Hide 82720 1.INSTALL ENGINE ROOM JUNCTION BLOCK ASSEMBLY

a.

Connect the 2 connectors.


b.
B286755

Connect the 4 connectors to the engine room relay block assembly.


c.

Engage the 2 claws to install the engine room junction block assembly.


Hide 82662A 2.INSTALL NO. 1 RELAY BLOCK COVER

a.
B286756

Engage the 2 claws to install the No. 1 relay block cover.


Hide 3.CONNECT CABLE TO AUXILIARY BATTERY NEGATIVE TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 64718C 4.INSTALL LUGGAGE TRIM SERVICE HOLE COVER