Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM › 2012.02–2015.04
RM2040EQ _57 Power Source / Network _014721 NETWORKING _0075042 CAN COMMUNICATION SYSTEM J

NETWORKING  CAN COMMUNICATION SYSTEM  Combination Meter ECU Communication Stop Mode  


DESCRIPTION

Detection Item Symptom Trouble Area
Combination Meter ECU Communication Stop Mode Either condition is met:
·

"Combination Meter" is not displayed on the "Communication Bus Check" screen of the intelligent tester

Click here(Click here)

·

Communication system DTCs (DTCs that start with U) that are output correspond to "Combination Meter ECU Communication Stop Mode" in "DTC Combination Table"

Click here(Click here)


·

Combination meter assembly main line or connector

·

Power source circuit of combination meter assembly

·

Combination meter assembly ground circuit

·

Combination meter assembly



WIRING DIAGRAM

C252902E13
5.135,2.51 5.031,2.51 5.031,2.51 4.875,3.052 false 3.875,4.552 3.875,4.844 3.875,4.844 4.094,4.844 false 1.417,5.031 2.396,5.271 0.979,0.24 10 false Trouble Area 3.958,2.333 4.51,2.552 0.552,0.219 10 false DLC3 1.292,0.563 3.792,0.896 2.5,0.333 10 false : CAN Main Bus Line (CANH) 1.281,0.906 3.781,1.24 2.5,0.333 10 false : CAN Main Bus Line (CANL) 1.281,1.26 3.021,1.594 1.74,0.333 10 false : CAN Branch Line (CANH) 1.271,1.594 3.01,1.927 1.74,0.333 10 false : CAN Branch Line (CANL) 1.281,4.615 3.24,4.865 1.958,0.25 10 false Combination Meter Assembly 1.698,3.104 1.969,3.396 0.271,0.292 10 false B 1.688,3.635 2.052,3.938 0.365,0.302 10 false IG+ 1.719,4.271 2.094,4.531 0.375,0.26 10 false ES 1.302,4.406 1.688,4.635 0.385,0.229 10 false I18 2.396,3.958 2.885,4.24 0.49,0.281 10 false CANL 2.385,3.073 2.875,3.344 0.49,0.271 10 false CANH 2.26,4.198 2.708,4.49 0.448,0.292 10 false 120 Ω 6.167,4.167 6.677,4.427 0.51,0.26 10 false 120 Ω 1.521,4.146 1.688,4.396 0.167,0.25 10 false 7 2.865,3.073 3.125,3.344 0.26,0.271 10 false 16 2.854,3.958 3.125,4.24 0.271,0.281 10 false 15 0.719,3.26 1.656,3.573 0.938,0.313 10 false ECU-B NO. 1 0.76,3.813 1.688,4.104 0.927,0.292 10 false METER-IG2 1.521,2.99 1.823,3.271 0.302,0.281 10 false 1 1.479,3.542 1.75,3.802 0.271,0.26 10 false 13 4.188,4.76 5.365,5.177 1.177,0.417 10 false CAN Junction RH1 Connector 5.219,2.406 7.115,2.719 1.896,0.313 10 false CAN Junction LH1 Connector 6.313,4.604 6.802,4.844 0.49,0.24 10 false ECM 0.156,0.135 1.073,0.521 0.917,0.385 12 false V Bus: 5.99,4.604 6.385,4.854 0.396,0.25 10 false A25

CAUTION / NOTICE / HINT

NOTICE:
·

Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key, switches or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.

·

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING

·

After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.

·

DTC check procedure: Turn the power switch on (IG), turn the blind spot monitor main switch on, wait at least 60 seconds.

·

After the repair, perform Communication Bus Check and check that all the ECUs and sensors connected to the CAN communication system are displayed.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM



HINT:
·

Operating the power switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.

·

Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.



PROCEDURE

1.CHECK FOR OPEN IN CAN BUS LINES (COMBINATION METER ASSEMBLY MAIN LINE)
a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the combination meter assembly connector.


c.
E224284C08
1.24,0.521 1.729,0.813 0.49,0.292 1.365,2.167 1.365,2.51 1.365,2.51 1.552,2.51 false 1.24,2.156 1.24,2.51 1.24,2.51 1.052,2.51 false 0.156,0.177 0.438,0.458 0.281,0.281 10 false *a 1.583,2.417 2.115,2.656 0.531,0.24 10 false CANH 0.573,2.417 1.104,2.656 0.531,0.24 10 false CANL 1.375,0.594 1.656,0.771 0.281,0.177 10 false I18
*a Front view of wire harness connector
(to Combination Meter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I18-16 (CANH) - I18-15 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)

NG

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (COMBINATION METER ASSEMBLY MAIN LINE)

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.
E224284C24
1.427,0.677 1.854,0.938 0.427,0.26 0.979,2.156 0.979,2.531 0.979,2.531 1.219,2.531 false 0.948,1.958 0.667,1.958 false 1.729,2 1.979,2.573 1.979,2.573 2.156,2.573 false 0.167,0.115 0.646,0.469 0.479,0.354 10 false *a 1.563,0.74 2.042,1.052 0.479,0.313 10 false I18 0.531,1.896 0.906,2.167 0.375,0.271 10 false B 1.271,2.469 1.854,2.823 0.583,0.354 10 false IG+ 2.24,2.479 2.573,2.74 0.333,0.26 10 false ES
*a Front view of wire harness connector
(to Combination Meter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I18-7 (ES) - Body ground Cable disconnected from negative (-) auxiliary batter yterminal Below 1 Ω



b.

Connect the cable to the negative (-) auxiliary battery terminal.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
I18-13 (IG+) - Body ground Power switch on (IG) 11 to 14 V
I18-1 (B) - Body ground Power switch off 11 to 14 V



Result:
Result
OK
NG



OK

REPLACE COMBINATION METER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)