The illuminated entry system controls the power switch illumination.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Entry&Start / Active Test.
Check that the illumination operates.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Power/Engine SW Light | Power switch light | OFF/ON | When performing this Active Test, make sure the following condition is met:
The power switch illumination is off (15 seconds or more have elapsed since it turned from on to off) and the power switch is on (ACC) or on (IG), or the hybrid control system is running. |
| Tester Display |
|---|
| Power/Engine SW Light |
Power switch illumination comes on.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the power switch.
Click hereEngine / Hybrid System>2AR-FXE STARTING>POWER SWITCH>REMOVAL
Inspect the power switch.
Click hereEngine / Hybrid System>2AR-FXE STARTING>POWER SWITCH>INSPECTION
Power switch illumination comes on.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I87 and I86 certification ECU (smart key ECU assembly) connector.
Disconnect the I58 power switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I58-9 (SWIL) - I87-6 (SWIL) | Always | Below 1 Ω |
| I58-6 (AGND) - I86-6 (AGND) | Always | Below 1 Ω |
| I58-9 (SWIL) - Body ground | Always | 10 kΩ or higher |
| I58-6 (AGND) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG