The evaporator temperature sensor (No. 1 cooler thermistor) is installed on the evaporator in the air conditioner unit to detect the temperature of the air that has passed through the evaporator. Its signal is used for air conditioing control. It sends signals to the air conditioning amplifier assembly. The resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the evaporator temperature sensor (No. 1 cooler thermistor) and reads voltage changes as the resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes. This sensor is used for frost prevention.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1413/13 | Evaporator Temperature Sensor Circuit | Open or short in evaporator temperature sensor (No. 1 cooler thermistor) circuit | ·
Evaporator temperature sensor (No. 1 cooler thermistor) ·
Air conditioning harness assembly ·
Air conditioning amplifier assembly |
Memorized
(4 sec. or more)*1 |
*1: The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the brackets.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evaporator Fin Thermistor | Evaporator temperature sensor (No. 1 cooler thermistor) | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Tester Display |
|---|
| Evaporator Fin Thermistor |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>PROBLEM SYMPTOMS TABLE
C
Remove the evaporator temperature sensor (No. 1 cooler thermistor).
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>REMOVAL
| *a | Component without harness connected
(Evaporator Temperature Sensor (No. 1 Cooler Thermistor)) |
*b | Sensing Portion |
| *c | Resistance (kΩ) | *d | Temperature (°C (°F)) |
| *e | Allowable Range | - | - |
Disconnect the a1 evaporator temperature sensor (No. 1 cooler thermistor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| a1-1 - a1-2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| a1-1 - a1-2 | -5°C (23°F) | 5.65 to 6.95 kΩ |
| a1-1 - a1-2 | 0°C (32°F) | 4.40 to 5.35 kΩ |
| a1-1 - a1-2 | 5°C (41°F) | 3.40 to 4.15 kΩ |
| a1-1 - a1-2 | 10°C (50°F) | 2.70 to 3.25 kΩ |
| a1-1 - a1-2 | 15°C (59°F) | 2.14 to 2.58 kΩ |
| a1-1 - a1-2 | 20°C (68°F) | 1.71 to 2.05 kΩ |
| a1-1 - a1-2 | 25°C (77°F) | 1.38 to 1.64 kΩ |
| a1-1 - a1-2 | 30°C (86°F) | 1.11 to 1.32 kΩ |
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Air Conditioning Amplifier Assembly) |
Remove the air conditioning harness assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT>DISASSEMBLY
| *a | Front view of wire harness connector
(to Evaporator Temperature Sensor (No. 1 Cooler Thermistor)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z1-6 (TEA) - a1-2 | Always | Below 1 Ω |
| z1-5 (SGA) - a1-1 | Always | Below 1 Ω |
| z1-6 (TEA) - Body ground | Always | 10 kΩ or higher |
| z1-5 (SGA) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG