Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2015.04
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A10-263  DC / DC Converter Status Circuit High Input  


DESCRIPTION

Refer to the description for DTC P0A08-264 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A08-264).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A10-263 DC / DC Converter Status Circuit High Input Short to +B in the hybrid vehicle converter (DC/DC converter) NODD signal line
·

Wire harness or connector

·

Inverter with converter assembly

·

Power management control ECU


Does not come on Master Warning Light:
Comes on

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A08-264 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A08-264).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK POWER MANAGEMENT CONTROL ECU (NODD)

OK

2.CLEAR DTC

NG

5.CHECK POWER MANAGEMENT CONTROL ECU (NODD)
2.CLEAR DTC

NEXT

3.CHECK DTC OUTPUT (HYBRID CONTROL)
3.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (READY).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
P0A10-263 is not output. A
P0A10-263 is output again. B



e.

Turn the power switch off.



A

4.CHECK FOR INTERMITTENT PROBLEMS

B

4.CHECK FOR INTERMITTENT PROBLEMS

OK

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

5.CHECK POWER MANAGEMENT CONTROL ECU (NODD)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A13 from the inverter with converter assembly.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
A258452C15
1.5,0.385 1.917,0.625 0.417,0.24 1.448,1.354 1.031,1.625 false 0.24,0.146 0.49,0.333 0.25,0.188 10 false *a 0.615,1.583 1.115,1.781 0.5,0.198 10 false NODD 1.583,0.417 1.854,0.583 0.271,0.167 10 false A13
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A13-5 (NODD) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Connect the inverter with converter assembly connector.

Result:
Proceed to
OK
NG




OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)
6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A13 from the inverter with converter assembly.


c.

Disconnect connector A38 from the power management control ECU.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.
A259909C36
1.542,0.313 1.958,0.552 0.417,0.24 1.302,3.813 1.719,4.052 0.417,0.24 1.49,1.333 0.948,1.583 false 0.906,3.969 1.219,4.333 false 0.177,0.156 0.542,0.375 0.365,0.219 10 false *a 0.531,1.542 1.104,1.833 0.573,0.292 10 false NODD 0.188,2.208 0.552,2.5 0.365,0.292 10 false *b 1.063,4.365 1.531,4.615 0.469,0.25 10 false NODD 1.615,0.354 2,0.594 0.385,0.24 10 false A13 1.385,3.865 1.75,4.135 0.365,0.271 10 false A38
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Rear view of wire harness connector
(to Power Management Control ECU)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A13-5 (NODD) or A38-23 (NODD) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector and the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal.


i.

Connect the inverter with converter assembly connector.


j.

Connect the power management control ECU connector.

Result:
Proceed to
OK
NG




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR