Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2015.04
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P2511-149  HV CPU Power Relay Sense Circuit Intermittent No Continuity  


DESCRIPTION

This DTC indicates that the power management control ECU monitors the +B power source voltage to detect an instantaneous interruption.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P2511-149 HV CPU Power Relay Sense Circuit Intermittent No Continuity When the power switch is on (READY), the power management control ECU is reset.
·

Wire harness or connector

·

Power management control ECU


Does not come on Master Warning Light:
Comes on

WIRING DIAGRAM

Refer to the wiring diagram for DTC P3110-223 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P3110-223).

PROCEDURE

1.CHECK AUXILIARY BATTERY TERMINAL
a.

Confirm whether the auxiliary battery terminals have been disconnected recently.

Result:
Result Proceed to
Terminals have been disconnected. A
Terminals have not been disconnected. B




A

2.CONFIRM THAT MASTER WARNING LIGHT

B

5.CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM)
2.CONFIRM THAT MASTER WARNING LIGHT
a.

Turn the power switch on (READY) from off.


b.

Confirm that the master warning light illuminates.

Result:
Result Proceed to
Master warning light illuminates. A
Master warning light does not illuminates. B


HINT:

DTC P2511-149 may be stored after disconnecting and reconnecting the auxiliary battery terminals. If this happens, the DTC will not be output if the power switch is turned off and then on (READY) again. In this case, clear DTCs to complete the inspection.



c.

Turn the power switch off.



A

3.CLEAR DTC

B

END

3.CLEAR DTC
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Read and record the DTCs and freeze frame data.


e.

Clear the DTCs and freeze frame data.

Powertrain > Hybrid Control > Clear DTCs
50002 236

f.

Turn the power switch off.

Result:
Proceed to
NEXT




NEXT

4.CHECK DTC OUTPUT (HYBRID CONTROL)
4.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
P2511-149 is output again. A
DTCs other than P2511-149 are also output. B



e.

Turn the power switch off.



A

5.CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM)

B

5.CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM)
a.

Check the connection of the auxiliary battery terminal.

OK:

The terminal is connected securely and there is no contact problem.


Result:
Proceed to
OK
NG




OK

6.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

NG

CONNECT SECURELY

6.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

7.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - IGCT RELAY)

NG

CONNECT SECURELY

7.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - IGCT RELAY)
a.

Remove the IGCT relay from the No. 2 engine room relay block.


b.

Disconnect connectors A38 and A39 from power management control ECU.

A259914C10
1.281,2.354 1.615,2.552 0.333,0.198 1.833,2.354 2.167,2.552 0.333,0.198 1.573,1.719 1.708,2.083 false 2,1.729 2.313,2.094 false 0.844,0.146 1.198,0.365 0.354,0.219 10 false *a 3.948,0.146 4.302,0.365 0.354,0.219 10 false *1 5.854,1.656 6.198,1.948 0.344,0.292 10 false *2 2.26,2.115 2.677,2.344 0.417,0.229 10 false +B1 1.583,2.135 1.927,2.313 0.344,0.177 10 false +B2 1.344,2.385 1.823,2.635 0.479,0.25 10 false A38 1.896,2.385 2.354,2.635 0.458,0.25 10 false A39
*1 No. 2 Engine Room Relay Block *2 IGCT Relay
*a Rear view of wire harness connector
(to Power Management Control ECU)
- -



c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A39-3 (+B1) - 5 (IGCT relay) Power switch off Below 1 Ω
A38-1 (+B2) - 5 (IGCT relay) Power switch off Below 1 Ω



d.

Install the IGCT relay.


e.

Connect the power management control ECU connector.

Result:
Proceed to
OK
NG




OK

8.CHECK FOR INTERMITTENT PROBLEMS

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK FOR INTERMITTENT PROBLEMS
a.

Check for intermittent problems (Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>CHECK FOR INTERMITTENT PROBLEMS).

i.

Check the connection and terminal contact pressure of connectors and wire harnesses between the power management control ECU and the No. 2 engine room relay block.


ii.

When the power switch is on (READY), jiggle the connectors and wire harnesses between the power management control ECU and the No. 2 engine room relay block.

Result:
Result Proceed to
Problem symptom does not recur. A
Problem symptom recurs. B





A

B

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA