Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2016.05
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0E05-328  Generator Phase V Current Sensor Circuit Range / Performance  P0E09-336  Generator Phase W Current Sensor Circuit Range / Performance  P1C3E-333  Generator Phase V Current Sensor Correlation  P1C3F-341  Generator Phase W Current Sensor Correlation  P1C54-326  Generator Phase V Current Sensor Sub Circuit Range / Performance  P1C59-334  Generator Phase W Current Sensor Sub Circuit Range / Performance  P1C71-515  Generator Phase V Current Sensor Offset Range / Performance  P1C72-516  Generator Phase W Current Sensor Offset Range / Performance  


DESCRIPTION

The MG ECU located in the inverter with converter assembly monitors the generator inverter current sensors. DTCs P0E05-328, P0E09-336, P1C3E-333, P1C3F-341, P1C54-326, P1C59-334, P1C71-515 or P1C72-516 indicate malfunctions in the current sensors, and they do not indicate malfunctions in the high-voltage system.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0E05-328 Generator Phase V Current Sensor Circuit Range / Performance Malfunction in generator inverter current sensor (phase V main sensor) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P0E09-336 Generator Phase W Current Sensor Circuit Range / Performance Malfunction in generator inverter current sensor (phase W main sensor) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1C3E-333 Generator Phase V Current Sensor Correlation Malfunction in generator inverter current sensor (performance problem or open phase V) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1C3F-341 Generator Phase W Current Sensor Correlation Malfunction in generator inverter current sensor (performance problem or open phase W) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1C54-326 Generator Phase V Current Sensor Sub Circuit Range / Performance Malfunction in generator inverter current sensor (phase V sub sensor) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1C59-334 Generator Phase W Current Sensor Sub Circuit Range / Performance Malfunction in generator inverter current sensor (phase W sub sensor) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1C71-515 Generator Phase V Current Sensor Offset Range / Performance Malfunction in generator inverter current sensor (phase V main and sub sensors offset) Inverter with converter assembly Comes on Master Warning Light:
Comes on
P1C72-516 Generator Phase W Current Sensor Offset Range / Performance Malfunction in generator inverter current sensor (phase W main and sub sensors offset) Inverter with converter assembly Comes on Master Warning Light:
Comes on

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
Only DTC P0E05-328, P0E09-336, P1C3E-333, P1C3F-341, P1C54-326, P1C59-334, P1C71-515 or P1C72-516 are output or any DTCs other than P0A7A-203 is also output. A
P0A7A-203 is output. B



e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

CONNECT SECURELY