Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2016.05
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A78-548  Drive Motor "A" Inverter Performance  


DESCRIPTION

For a description of the boost converter (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0CA3-442).

If a malfunction occurs in the boost converter, the MG ECU detects it and transmits this information to the power management control ECU.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A78-548 Drive Motor "A" Inverter Performance Boost converter overvoltage signal detection (overvoltage due to inverter assembly malfunction) Inverter with converter assembly Comes on Master Warning Light:
Comes on

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
P0A78-548 only is output. A
Any of the following DTCs are also output. B


DTC No. Relevant Diagnosis
P06B0-163 Sensor Power Supply "A" Circuit / Open
P06D6-511 Sensor Reference Voltage "F" Circuit / Open
P06E6-164 Sensor Power Supply "C" Circuit / Open
P0A1A-151, 166, 517, 658, 791, 809 Generator Control Module
P0A1B-198, 505, 554, 786, 794, 806 Drive Motor "A" Control Module
P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
P0A3F-243 Drive Motor "A" Position Sensor Circuit
P0A40-500, 506, 556, 808 Drive Motor "A" Position Sensor Circuit Range / Performance
P0A41-245 Drive Motor "A" Position Sensor Circuit Low
P0A4B-253 Generator Position Sensor Circuit
P0A4C-513, 518, 811 Generator Position Sensor Circuit Range / Performance
P0A4D-255 Generator Position Sensor Circuit Low
P0A78-287, 555, 807 Drive Motor "A" Inverter Performance
P0A7A-325, 810 Generator Inverter Performance
P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
P0BEA-290 Drive Motor "A" Phase V Current Sensor Circuit Range / Performance
P0BEE-298 Drive Motor "A" Phase W Current Sensor Circuit Range / Performance
P0C76-523 Hybrid Battery System Discharge Time Too Long
P0D2E-586 Drive Motor "A" Inverter Voltage Sensor Circuit Range / Performance
P0D2F-266 Drive Motor "A" Inverter Voltage Sensor Circuit Low
P0D30-267 Drive Motor "A" Inverter Voltage Sensor Circuit High
P0E05-328 Generator Phase V Current Sensor Circuit Range / Performance
P0E09-336 Generator Phase W Current Sensor Circuit Range / Performance
P0E32-564, 585 DC/DC Converter Voltage Sensor "A" Range / Performance
P0E33-589 DC/DC Converter Voltage Sensor "A" Low
P0E34-590 DC/DC Converter Voltage Sensor "A" High
P1C2A-155 Generator A/D Converter Circuit
P1C2B-192 Drive Motor "A" A/D Converter Circuit
P1C2D-587 Hybrid Battery Voltage / DC/DC Converter Voltage Correlation
P1C3C-294 Drive Motor "A" Phase V Current Sensor Correlation
P1C3D-302 Drive Motor "A" Phase W Current Sensor Correlation
P1C3E-333 Generator Phase V Current Sensor Correlation
P1C3F-341 Generator Phase W Current Sensor Correlation
P1C4A-288 Drive Motor "A" Phase V Current Sensor Sub Circuit Range / Performance
P1C4F-296 Drive Motor "A" Phase W Current Sensor Sub Circuit Range / Performance
P1C54-326 Generator Phase V Current Sensor Sub Circuit Range / Performance
P1C59-334 Generator Phase W Current Sensor Sub Circuit Range / Performance
P1C6D-501 Drive Motor "A" Phase V Current Sensor Offset Range / Performance
P1C6E-502 Drive Motor "A" Phase W Current Sensor Offset Range / Performance
P1C71-515 Generator Phase V Current Sensor Offset Range / Performance
P1C72-516 Generator Phase W Current Sensor Offset Range / Performance
P1C73-512 Sensor Standard Voltage "F" Circuit / Open
P1CA6-156 Generator Control Module Malfunction
P1CA7-193 Drive Motor Control Module Malfunction
P1CAC-200 Generator Position Sensor Angle Malfunction
P1CAD-168 Drive Motor "A" Position Sensor Angle Malfunction
P1CAF-792 Generator Position Sensor REF Signal Cycle Malfunction
P1CB0-795 Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
P1CB2-793 Generator Position Sensor REF Signal Stop Malfunction
P1CB3-796 Drive Motor "A" Position Sensor REF Signal Stop Malfunction
P3004-803 High Voltage Power Resource
P3133-659 Communication Error from Generator to Drive Motor "A"
P3134-661 Communication Error from Drive Motor "A" to Generator

HINT:
·

*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

·

P0A78-548 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.




e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

CONNECT SECURELY