Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2016.05
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  U0110-160  Lost Communication with Drive Motor Control Module "A"  


DESCRIPTION

For a description of the inverter (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0D2F-266).

The MG ECU located in the inverter with converter assembly controls MG2 based on commands from the power management control ECU. The MG ECU monitors communication data and detects malfunctions.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
U0110-160 Lost Communication with Drive Motor Control Module "A" Error in signal transmission to the inverter with converter assembly (MG ECU) via serial communication (no transmission, out of communication standard)
·

Wire harness or connector

·

Inverter with converter assembly

·

Hybrid vehicle transaxle assembly

·

Power management control ECU


Does not come on Master Warning Light:
Comes on

WIRING DIAGRAM

Refer to the wiring diagram for DTC U0110-159 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>U0110-159).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:
·

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).

·

If the DTC U0110-160 was set due to incomplete engagement of the connectors, and if the system returns to normal when the power switch is on (IG) after clearing the DTCs, DTC P324E-788 will be set. Proceed to troubleshooting without considering DTC P324E-788.



PROCEDURE

1.CLEAR DTC

NEXT

2.CHECK DTC OUTPUT (HYBRID CONTROL)
2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
DTC U0110-160 is output. A
DTC U0110-160 is not output. B



e.

Turn the power switch off.



A

3.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

B

3.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

A

4.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

4.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

A

5.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

5.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

OK

6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

NG

6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

OK

7.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM (HTM))

NG

7.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM (HTM))
a.

Connect an oscilloscope between the power management control ECU terminals specified in the following table.


b.

Turn the power switch on (IG).


c.
A283317C20
0.698,0.427 1.094,0.698 0.396,0.271 1.677,0.427 2.073,0.698 0.396,0.271 0.458,1.802 0.688,1.26 false 0.885,1.781 0.729,1.271 false 1.927,1.719 1.74,1.083 false 0.115,0.115 0.448,0.396 0.333,0.281 10 false *a 0.271,1.833 0.729,2.083 0.458,0.25 10 false HTM+ 0.75,1.813 1.229,2.042 0.479,0.229 10 false HTM- 1.958,1.813 2.333,2.125 0.375,0.313 10 false E1 2.781,4.031 3.24,4.229 0.458,0.198 10 false GND 2.802,3.479 3.26,3.677 0.458,0.198 10 false GND 0.219,3.104 0.677,3.302 0.458,0.198 10 false CH1 0.219,3.844 0.677,4.042 0.458,0.198 10 false CH2 0.781,0.49 1.24,0.688 0.458,0.198 10 false A38 1.823,0.49 2.208,0.75 0.385,0.26 10 false I3
*a Component with harness connected
(Power Management Control ECU)


Measure the waveform.

Item Contents
Tester Connection CH1: A38-34 (HTM+) - I3-6 (E1)
CH2: A38-33 (HTM-) - I3-6 (E1)
Equipment Setting 1V/DIV., 200μs/DIV.
Condition Power switch on (IG)

Result:
Result Proceed to
The waveform appears as shown in the illustration. A
The waveform differs from the one shown in the illustration. B


HINT:
·

Inspect with the connector connected.

·

If pulses are generated, the shape of the waveform can be assumed to be normal.

·

The shape of the waveform may vary according to communication conditions.




d.

Turn the power switch off.



A

8.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM (CLK))

B

10.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY (HTM))
8.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM (CLK))

A

9.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM (REQ))

B

12.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY (CLK))
9.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM (REQ))

A

B

14.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY (REQ))
10.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY (HTM))
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A38 from the power management control ECU.


c.

Disconnect connector A14 from the inverter with converter assembly.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.
A319047C13
0.135,1.729 0.521,1.958 0.385,0.229 0.24,3.448 0.625,3.677 0.385,0.229 0.385,2.469 0.635,1.969 true 0.906,2.438 0.698,1.958 true 1.302,4.25 1.917,3.323 true 2.021,4.24 1.927,3.417 true 0.188,0.177 0.5,0.375 0.313,0.198 10 false *a 0.344,2.854 0.656,3.052 0.313,0.198 10 false *b 0.219,1.781 0.531,1.979 0.313,0.198 10 false A38 0.323,3.51 0.635,3.708 0.313,0.198 10 false A14 0.802,2.479 1.188,2.677 0.385,0.198 10 false HTM- 0.188,2.49 0.604,2.698 0.417,0.208 10 false HTM+ 1.135,4.281 1.583,4.51 0.448,0.229 10 false HTM+ 1.917,4.271 2.302,4.469 0.385,0.198 10 false HTM-
*a Rear view of wire harness connector
(to Power Management Control ECU)
*b Front view of wire harness connector
(to Inverter with Converter Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A38-34 (HTM+) - Body ground Power switch on (IG) Below 1 V
A38-33 (HTM-) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the power management control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
A38-34 (HTM+) - A14-9 (HTM+) Power switch off Below 1 Ω
A38-33 (HTM-) - A14-20 (HTM-) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Switch Condition Specified Condition
A38-34 (HTM+) or A14-9 (HTM+) - Body ground and other terminals Power switch off 10 kΩ or higher
A38-33 (HTM-) or A14-20 (HTM-) - Body ground and other terminals Power switch off 10 kΩ or higher



i.

Disconnect the cable from the negative (-) auxiliary battery terminal.


j.

Connect the inverter with converter assembly connector.


k.

Connect the power management control ECU connector.

Result:
Proceed to
OK
NG




OK

11.CHECK INVERTER WITH CONVERTER ASSEMBLY (HTM)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

11.CHECK INVERTER WITH CONVERTER ASSEMBLY (HTM)
a.

Disconnect connector A38 from the power management control ECU.


b.
A204443C84
0.104,2.354 0.479,2.594 0.375,0.24 0.646,2.573 0.813,3.073 false 0.594,2.573 0.417,3.083 false 0.104,0.083 0.375,0.292 0.271,0.208 10 false *a 0.25,3.125 0.74,3.292 0.49,0.167 10 false HTM+ 0.677,3.125 1.208,3.313 0.531,0.188 10 false HTM- 0.177,2.406 0.49,2.604 0.313,0.198 10 false A38
*a Rear view of wire harness connector
(to Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A38-34 (HTM+) - A38-33 (HTM-) Power switch off 80 to 170 Ω



c.

Connect the power management control ECU connector.

Result:
Proceed to
OK
NG




OK

NG

12.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY (CLK))

OK

13.CHECK INVERTER WITH CONVERTER ASSEMBLY (CLK)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

13.CHECK INVERTER WITH CONVERTER ASSEMBLY (CLK)

OK

NG

14.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY (REQ))

OK

15.CHECK INVERTER WITH CONVERTER ASSEMBLY (REQ)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

15.CHECK INVERTER WITH CONVERTER ASSEMBLY (REQ)

OK

NG