ENGINE IMMOBILISER SYSTEM > Security Indicator Light Does not Blink |

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SECURITY INDICATOR LIGHT) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Entry&Start / Active Test.
Perform the Active Test according to the display on the intelligent tester.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Immobiliser Indicator | Security indicator light | OFF/ON | - |
|
| ||||
| OK | |
| 2.CHECK SECURITY INDICATOR LIGHT OPERATION |
When the immobiliser is set, check that the security indicator light blinks.*1
When the theft deterrent system is in the arming preparation state, check that the security indicator light is on (Click here).*2
| Result | Proceed to |
| *1 is NG (*2 is OK) | A |
| *2 is NG (*1 is OK) | B |
|
| ||||
| A | ||
| ||
| 3.CHECK HARNESS AND CONNECTOR (SECURITY INDICATOR LIGHT (HEATER CONTROL SWITCH BOARD) - CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)) |
Disconnect the I56 security indicator light (heater control switch board) connector.
Disconnect the I86 certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I86-8 (IND)- I56-1 (LP) | Always | Below 1 Ω |
| I86-8 (IND) - Body ground | Always | 10 kΩ or higher |
| I56-6 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) |
Reconnect the I86 certification ECU (smart key ECU assembly) connector.
Measure the voltage and check the pulse according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I56-1 (LP) - I56-6 (GND) | Power switch off → power switch on (IG) | Pulse generation → Below 2 V |
|
| ||||
| OK | ||
| ||