DTC    P0A08-264    DC / DC Converter Status Circuit

for Preparation Click here


DESCRIPTION

The hybrid vehicle converter (DC/DC converter) converts the DC 244.8 V of the HV battery into DC 12 V in order to supply power to areas such as the vehicle's lighting, audio, and ECU systems. In addition, it charges the auxiliary battery. A transistor bridge circuit initially converts DC 244.8 V into alternating current, and a transformer lowers its voltage. Then, it is rectified and smoothed (into DC) and converted into DC 12 V. The hybrid vehicle converter controls the output voltage in order to keep a constant voltage at the terminals of the auxiliary battery.
The power management control ECU uses the NODD signal line to transmit a stop command to the hybrid vehicle converter and receive signals indicating the normal or abnormal condition of the 12 V charging system. If the vehicle is being driven with an inoperative hybrid vehicle converter, the voltage of the auxiliary battery will drop, which will prevent the continued operation of the vehicle. Therefore, the power management control ECU monitors the operation of the hybrid vehicle converter and alerts the driver if it detects a malfunction.

A217225E08


DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A08
264
The DC/DC converter is malfunctioning (charging has stopped) and the auxiliary battery voltage drops to 11 V or less.
(1 trip detection logic)
The DC/DC converter is malfunctioning for 120 seconds and the inverter coolant water temperature is 70°C or lower.
(1 trip detection logic)
  1. Wire harness or connector
  2. Inverter cooling system
  3. Hybrid vehicle transaxle assembly
  4. Inverter with converter assembly
  5. Fuse (DC/DC-S)
  6. Fusible link block assembly (DC/DC)
  7. No. 3 engine room wire
  8. Power management control ECU

WIRING DIAGRAM


A260107E04

Refer to the wiring diagram for DTC P0AA6-526 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

HINT:
  1. If the DC/DC converter is malfunctioning, the auxiliary battery cannot be charged. Therefore, once the power switch is turned off, it may be impossible to turn it on (READY) again if the auxiliary battery is completely discharged. In this case, charge the auxiliary battery. Be careful as charging is not performed during the inspection.
  2. If the power switch turns off immediately after it is turned on (READY), the auxiliary battery voltage may be low. Charge the auxiliary battery.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A08-264 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1B-547
    Drive Motor "A" Control Module
    P0A40-549
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A78-548
    Drive Motor "A" Inverter Performance
    P0A93-346
    Inverter Cooling System Performance
    P0AA6-526, 613
    Hybrid Battery Voltage System Isolation Fault
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE6-225
    Hybrid Battery Precharge Contactor Control Circuit Low
    P0C73-776
    Motor Electronics Coolant Pump "A" Control Performance
    P3004-131, 803
    High Voltage Power Resource
    P314A-828
    Inverter Coolant Pump Speed Signal

  1. Turn the power switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)
A


2.CHECK FUSE (DC/DC-S)


    A259800E01
  1. Remove the DC/DC-S fuse from the engine room relay block and junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    DC/DC-S fuse terminals
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Engine Room Relay Block and Junction Block Assembly
    *2
    DC/DC-S Fuse

  1. Install the DC/DC-S fuse.



NG
Go to step 21
OK


3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)


    A264189
  1. Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors (Click here).

    OK:
    The connectors are connected securely and there are no contact pressure problems.



NG
CONNECT SECURELY
OK


4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



  1. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

    NOTICE:
    Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.


    A258444E01

    OK:
    The connectors are connected securely and there are no contact pressure problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK


5.CHECK FUSIBLE LINK BLOCK ASSEMBLY (DC/DC)
  1. Check the fusible link block assembly (DC/DC) in the engine room relay block and junction block assembly for improper installation.

    OK:
    The fusible link is installed securely.

  1. Remove the fusible link block assembly from the engine room relay block and junction block assembly.



    A258447E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Fusible link block assembly (DC/DC) 1 - 2
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Fusible Link Block Assembly

  1. Install the fusible link block assembly.



NG
REPLACE FUSIBLE LINK BLOCK ASSEMBLY (DC/DC)
OK


6.CHECK CABLE AND WIRE HARNESS

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258636
  1. Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.



    A258637E09
  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    o3-1 (W) - Body ground and shield ground
    Power switch off
    1 MΩ or higher
    o3-2 (V) - Body ground and shield ground
    Power switch off
    1 MΩ or higher
    o3-3 (U) - Body ground and shield ground
    Power switch off
    1 MΩ or higher
    n3-1 (W) - Body ground and shield ground
    Power switch off
    1 MΩ or higher
    n3-2 (V) - Body ground and shield ground
    Power switch off
    1 MΩ or higher
    n3-3 (U) - Body ground and shield ground
    Power switch off
    1 MΩ or higher

    Text in Illustration  
    *1
    Generator Cable
    *2
    Motor Cable

    HINT:
    Perform this inspection while the generator cable and motor cable are connected.

  1. Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).



NG
Go to step 17
OK


7.CHECK AMD TERMINAL VOLTAGE (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY SIDE)

CAUTION:
Be sure to wear insulated gloves.

  1. Connect the cable to the negative (-) auxiliary battery terminal.



    A260097E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    1K-1 (AMD) - Body ground
    Power switch off
    Same as auxiliary battery voltage

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8.CHECK AMD TERMINAL CONNECTION CONDITION

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A259381
  1. Check that the bolt for the AMD terminal (inverter with converter assembly side and engine room relay block and junction block assembly side) is tightened to the specified torque, the AMD terminal (inverter with converter assembly side and engine room relay block and junction block assembly side) is connected securely, and there is no contact problem.

    Torque:
    T=18 N*m {184 kgf*cm, 13ft.*lbf } (Inverter with converter assembly side)
    T=8.0 N*m {82 kgf*cm, 71in.*lbf } (Engine room relay block and junction block assembly side)

    Result:
    Result
    Proceed to
    There are no arc marks.
    The terminal is connected securely and there is no contact problem.
    A
    There are no arc marks.
    The terminal is not connected securely and there is a contact problem.
    B
    There are arc marks.
    -
    C



B
CONNECT SECURELY

C
REPLACE MALFUNCTIONING PARTS
A


9.CHECK NO. 3 ENGINE ROOM WIRE

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect No. 3 engine room wire from the AMD terminal (inverter with converter assembly side and engine room relay block and junction block assembly side).



    A259734E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C1-1 (AMD) - 1K-1 (AMD)
    Always
    Below 1 Ω

    Text in Illustration  
    *1
    No. 3 Engine Room Wire

  1. Connect No. 3 engine room wire.



NG
REPLACE NO. 3 ENGINE ROOM WIRE
OK


10.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - DC/DC-S FUSE)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A13 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.



    A258452E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    A13-3 (S) - Body ground
    Always
    Same as auxiliary battery voltage

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


11.CHECK HARNESS AND CONNECTOR (RESISTANCE VALUE OF NODD INSIDE POWER MANAGEMENT CONTROL ECU)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A13 from the inverter with converter assembly.



    A258452E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A13-5 (NODD) - Body ground
    Power switch off
    110 to 150 kΩ

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 19
OK


12.CHECK DC/DC CONVERTER FUNCTION

HINT:
The current at the AMD terminal cannot be measured directly because of space limitations. Measure the current flowing at the auxiliary battery instead.



    A174427E02
  1. Connect the AC/DC 400 A probe to the positive auxiliary battery line.

  1. Install the service plug grip.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.

    HINT:
    If the power switch turns off immediately after it is turned on (READY), auxiliary battery voltage may be low. Recharge the auxiliary battery and perform this procedure again.



    A174428E02
  1. Measure the current flowing from the auxiliary battery with the power switch on (READY), the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.

    Standard Current:
    Item
    Condition
    Specified Condition
    Current flowing from auxiliary battery
    Power switch on (READY)
    (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)
    0 A or less
    (no current from auxiliary battery)

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Item
    Condition
    Specified Condition
    Auxiliary battery voltage
    Power switch on (READY)
    (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)
    13 to 15 V

  1. Turn the power switch off.



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK


13.CHECK QUANTITY OF HV COOLANT
  1. Check the HV coolant level in the inverter reserve tank.

  1. Check for HV coolant leaks.
    Result 
    Result
    Proceed to
    No leaks are found and coolant level in the inverter reserve tank assembly is above the low line.
    A
    No leaks are found and coolant level in the inverter reserve tank assembly is below the low line.
    B
    HV coolant leaks are evident.
    C

    HINT:
    After repairing the HV coolant leaks and adding coolant, perform the "Activate the Water Pump" Active Test (HV Active Test item) and the "Control the Electric Cooling Fan" Active Test (Engine Active Test item) and make sure that there are no malfunctions.



B
ADD HV COOLANT

C
INSPECT FOR HV COOLANT LEAK AND ADD HV COOLANT
A


14.CHECK COOLANT HOSE
  1. Check if the hoses of the cooling system are kinked or clogged.



NG
CORRECT THE PROBLEM
OK


15.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE ELECTRIC COOLING FAN)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.

  1. Perform the "Control the Electric Cooling Fan" Active Test.

    OK:
    The cooling fan rotates.

  1. Turn the power switch off.



NG
CHECK COOLING FAN SYSTEM (Click here)
OK


16.CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Read the freeze frame data Ambient Temperature using the intelligent tester.

  1. Check if the freeze frame data Ambient Temperature is below freezing.

    Result:
    Result
    Proceed to
    Ambient Temperature value is above freezing temperature of the HV coolant.
    A
    Ambient Temperature value is below freezing temperature of the HV coolant.
    B

    HINT:
    1. HV coolant (SLLC) with a 30% concentration freezes at -15 °C (5°F) and HV coolant (SLLC) with a 50% concentration freezes at -35°C (-31°F).
    2. If the HV coolant freezes in the HV radiator or HV water pump, the coolant temperature in the inverter with converter assembly rises because the HV coolant cannot circulate. As a result, a DTC may be set.
    3. A DTC is set when the water pump impeller cannot rotate due to freezing of the HV coolant.
    4. If a DTC is set due to freezing of HV coolant, the problem cannot be reproduced. Judge whether freezing of HV coolant occurred according to the freeze point of the HV coolant, HV coolant change history and ambient temperature when the DTC was set.

  1. Turn the power switch off.



B
Go to step 20
A

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

17.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258951
  1. Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.



    A258953E01
  1. Disconnect the generator cable from the inverter with converter assembly.
    Text in Illustration 
    *1
    Generator Cable



    A258955E13
  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    o3-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    o3-2 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    o3-3 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Shield Ground
    *a
    Generator Cable

  1. Connect the generator cable.

  1. Install the upper inverter cover.



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK


18.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258952
  1. Remove the upper inverter cover (motor cable side) from the inverter with converter assembly.



    A258954E01
  1. Disconnect the motor cable from the inverter with converter assembly.
    Text in Illustration 
    *1
    Motor Cable



    A258955E14
  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    n3-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    n3-2 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    n3-3 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Shield Ground
    *a
    Motor Cable

  1. Connect the motor cable.

  1. Install the upper inverter cover.



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

19.INSPECT POWER MANAGEMENT CONTROL ECU (RESISTANCE VALUE OF NODD INSIDE POWER MANAGEMENT CONTROL ECU)


    A204442E49
  1. Disconnect all the connectors from the power management control ECU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A38-23 (NODD) - I3-6 (E1)
    Power switch off
    110 to 150 kΩ

    Text in Illustration 
    *a
    Component without harness connected
    (Power Management Control ECU)

  1. Connect the power management control ECU connectors.



NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

20.REPLACE HV COOLANT
  1. Replace the HV coolant with coolant having an appropriate concentration (appropriate freeze point) for the vehicle usage conditions (Click here).


NEXT

COMPLETED 

21.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - DC/DC-S FUSE)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A13 from the inverter with converter assembly.



    A259800E01
  1. Remove the DC/DC-S fuse from the engine room relay block and junction block assembly.
    Text in Illustration 
    *1
    Engine Room Relay Block and Junction Block Assembly
    *2
    DC/DC-S Fuse



  1. Measure the resistance according to the value(s) in the table below.


    A259802E01


    Text in Illustration 
    *1
    Engine Room Relay Block and Junction Block Assembly
    *2
    DC/DC-S Fuse
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    -
    -

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A13-3 (S) or 2 (DC/DC-S fuse) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

  1. Install the DC/DC-S fuse.

  1. Connect the inverter with converter assembly connector.



NG
Go to step 23
OK


22.REPLACE INVERTER WITH CONVERTER ASSEMBLY
(Click here)

NEXT

REPLACE FUSE (DC/DC-S) 

23.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (DC/DC-S)