Home › Vehicle Interior › THEFT DETERRENT / KEYLESS ENTRY › SMART ENTRY AND START SYSTEM (for Start Function)

SMART ENTRY AND START SYSTEM (for Start Function) > Power Source Mode does not Change to ON (IG)

for Preparation Click here


DESCRIPTION

If the power switch is pressed with the electrical key transmitter sub-assembly in the cabin, the power management control ECU receives a signal and changes the power source mode.

HINT:
When the cable is disconnected and reconnected to the negative (-) auxiliary battery terminal, the power source mode returns to the state it was in before the cable was disconnected.


WIRING DIAGRAM


B388621E02


INSPECTION PROCEDURE

NOTICE:
  1. When using the intelligent tester with the power switch off, perform either of the following: 1) Turn a courtesy light switch on and off at intervals of 1.5 seconds or less until communication between the intelligent tester and vehicle begins, or 2) connect the intelligent tester to the vehicle, select the vehicle type under manual mode, and then enter the following menus:
    for Power Source Control: Body / Power Source Control / DTC.
    for Entry&Start: Body / Entry&Start / DTC.
  2. The smart entry and start system (for Start Function) uses a multiplex communication system (LIN communication system) and the CAN communication system. Inspect the communication function by following How to Proceed with Troubleshooting (Click here). Troubleshoot the smart entry and start system (for Start Function) after confirming that the communication systems are functioning properly.
  3. Make sure that no DTCs are output. If any DTCs are output, proceed to the Diagnostic Trouble Code Chart (Click here).
  4. If the smart entry and start system is disabled through the customize function, enable the system before performing troubleshooting (Click here).
  5. Inspect the fuses of circuits related to this system before performing the following inspection procedure.
  6. After completing repairs, confirm that the problem does not occur.


HINT:

Related Data List and Active Test Items 
Problem Symptom
Data List Item
Active Test Item
Power source mode does not change to on (IG) but does change to on (ACC)
Power Source Control
  1. Power Supply Condition
  2. IG1 Relay Monitor (Inside)
  3. IG2 Relay Monitor (Inside)
  4. IG1 Relay Monitor (Outside)
  5. IG2 Relay Monitor (Outside)
  6. IG1 Circuit
  7. IG2 Circuit
-

1.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - NO. 1 INTEGRATION RELAY)
  1. Disconnect the A39 connector from the power management control ECU.

  1. Disconnect the 1C and 1E connectors from the No. 1 integration relay.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A39-2 (IG2D) - 1C-8
    Always
    Below 1 Ω
    1E-2 - Body ground
    Always
    Below 1 Ω
    A39-2 (IG2D) or 1C-8 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.INSPECT NO. 1 INTEGRATION RELAY (IG2 RELAY)
  1. Remove the No. 1 integration relay (Click here).

  1. Inspect the No. 1 integration relay (Click here).



NG
REPLACE NO. 1 INTEGRATION RELAY (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the I4 connector from the power management control ECU.

  1. Disconnect the 3A and 3B connectors from the instrument panel junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    I4-2 (IG1D) - 3A-27
    Always
    Below 1 Ω
    3B-7 - Body ground
    Always
    Below 1 Ω
    I4-2 (IG1D) and 3A-27 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (IG1 NO. 1, IG1 NO. 2, IG1 NO. 3 AND IG1 NO. 4 RELAY)
  1. Remove the instrument panel junction block assembly (Click here).

  1. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly (Click here).



  1. Measure the resistance according to the value(s) in the table below.


    B281391E01


    Text in Illustration 
    *A
    for LHD
    *B
    for RHD
    *a
    Component without harness connected
    (Instrument Panel Junction Block Assembly)
    -
    -

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    1. 3E-1 - 3D-1
      (IG1 No. 1 relay)
    2. 3E-1 - 3D-36
      (IG1 No. 2 relay)
    3. 3E-1 - 3C-4
      (IG1 No. 3 relay)
    Auxiliary battery voltage not applied to terminals 3A-27 and 3B-7
    10 kΩ or higher
    Auxiliary battery voltage applied to terminals 3A-27 and 3B-7
    Below 1 Ω
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    1. 3F-1 - 3D-1
      (IG1 No. 1 relay)
    2. 3F-1 - 3D-36
      (IG1 No. 2 relay)
    3. 3F-1 - 3C-4
      (IG1 No. 3 relay)
    Auxiliary battery voltage not applied to terminals 3A-27 and 3B-7
    10 kΩ or higher
    Auxiliary battery voltage applied to terminals 3A-27 and 3B-7
    Below 1 Ω



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK


5.CHECK POWER MANAGEMENT CONTROL ECU
B229525E14
  1. Reconnect the A39 and I4 certification ECU (smart key ECU assembly) connectors.

  1. Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection
Condition
Specified Condition
A39-2 (IG2D) - Body ground
Power switch on (ACC) → Power switch on (IG)
1 V or less → 9 V or higher
I4-2 (IG1D) - Body ground
Power switch on (ACC) → Power switch on (IG)
1 V or less → 9 V or higher

Text in Illustration 
*a
Component with harness connected
(Power Management Control ECU)


NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK

CHECK RELAY CONTACT SIDE CIRCUIT