Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

AIR CONDITIONING SYSTEM > TERMINALS OF ECU

for Preparation Click here



AIR CONDITIONING AMPLIFIER ASSEMBLY

E226604E05

HINT:
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Terminal No.
(Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
I77-1 (IG+) - I77-14 (GND)
B - W-B
Power source (IG)
Power switch on (IG)
11 to 14 V
I77-1 (IG+) - I77-14 (GND)
B - W-B
Power source (IG)
Power switch off
Below 1 V
I77-4 (ECOS) - I77-14 (GND)
L - W-B
ECO mode switch (eco switch assembly) signal
Power switch on (IG)
ECO mode switch (eco switch assembly): on
Below 1 V
I77-4 (ECOS) - I77-14 (GND)
L - W-B
ECO mode switch (eco switch assembly) signal
Power switch on (IG)
ECO mode switch (eco switch assembly): off
11 to 14 V
I77-5 (TAM) - I77-13 (SG-2)
P - GR
Ambient temperature sensor signal
Power switch on (IG)
Ambient temperature: 25°C (77°F)
1.35 to 1.75 V
I77-5 (TAM) - I77-13 (SG-2)
P - GR
Ambient temperature sensor signal
Power switch on (IG)
Ambient temperature: 40°C (104°F)
0.9 to 1.2 V
I77-9 (PRE) - I77-13 (SG-2)
R - GR
Air conditioning pressure sensor signal
Power switch on (READY)
A/C system operating
Refrigerant pressure: Abnormal pressure (more than 3025 kPa (30.9 kgf/cm2, 439 psi))
4.80 V or higher
I77-9 (PRE) - I77-13 (SG-2)
R - GR
Air conditioning pressure sensor signal
Power switch on (READY)
A/C system operating
Refrigerant pressure: Abnormal pressure (less than 176 kPa (1.8 kgf/cm2, 25 psi))
Below 0.50 V
I77-9 (PRE) - I77-13 (SG-2)
R - GR
Air conditioning pressure sensor signal
Power switch on (READY)
A/C system operating
Refrigerant pressure: Normal pressure (less than 3025 kPa (30.9 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 25 psi))
0.50 to 4.80 V
I77-10 (S5-3) - I77-13 (SG-2)
V - GR
Power supply for air conditioning pressure sensor
Power switch on (IG)
A/C switch: on
4.75 to 5.25 V
I77-10 (S5-3) - I77-13 (SG-2)
V - GR
Power supply for air conditioning pressure sensor
Power switch on (IG)
A/C switch: off
Below 1 V
I77-11 (CANH) - I77-12 (CANL)
V - W
CAN communication system
CAN communication occurring
Pulse generation
I77-13 (SG-2) - Body ground
GR - Body ground
Ground for air conditioning pressure sensor, ambient temperature sensor
Always
Below 1 V
I77-14 (GND) - Body ground
W-B - Body ground
Ground for main power supply
Always
Below 1 V
I77-15 (PTC1) - Body ground
G - Body ground
Quick heater operation signal
  1. Power switch on (READY)
  2. ECO mode switch (eco switch assembly) off
  3. Blower motor on
  4. Temperature settings: MAX HOT
  5. Engine coolant temperature 70°C or lower
  6. Ambient temperature 10°C or lower
  7. IDH terminal signal less than 1 V (Inverter with converter assembly overload not detected)
11 to 14 V
I77-16 (PTC2) - Body ground
Y - Body ground*1
L - Body ground*2
Quick heater operation signal
  1. Power switch on (READY)
  2. ECO mode switch (eco switch assembly) off
  3. Blower motor on
  4. Temperature settings: MAX HOT
  5. Engine coolant temperature 70°C or lower
  6. Ambient temperature 10°C or lower
  7. IDH terminal signal less than 1 V (Inverter with converter assembly overload not detected)
11 to 14 V
I77-21 (B) - I77-14 (GND)
Y - W-B
Power source (Back-up)
Power switch off
11 to 14 V
I77-22 (BLW) - I77-14 (GND)
R - W-B
Blower motor speed control signal
Power switch on (IG)
Blower switch: LO
Pulse generation
(See waveform 1)
I77-26 (NAIN) - I77-14 (GND)
Y - W-B
Ion generator assembly operation condition signal
Power switch on (IG)
Blower switch: LO
Below 1 V
I77-26 (NAIN) - I77-14 (GND)
Y - W-B
Ion generator assembly operation condition signal
Power switch on (IG)
Blower switch: OFF
11 to 14 V
I77-27 (IDH) - I77-14 (GND)
SB - W-B
Inverter with converter assembly current over signal
Power switch on (IG)
4.75 to 5.25 V
I77-29 (TR) - I77-34 (SG-1)
P - LG
Room temperature sensor signal
Power switch on (IG)
Cabin temperature: 25°C (77°F)
1.8 to 2.2 V
I77-29 (TR) - I77-34 (SG-1)
P - LG
Room temperature sensor signal
Power switch on (IG)
Cabin temperature: 40°C (104°F)
1.2 to 1.6 V
I77-32 (TSP) - I77-14 (GND)
R - W-B*1
Y - W-B*2
Solar sensor signal (for Front passenger side)
Power switch on (IG)
Solar sensor subjected to electric light
0.8 to 4.3 V
I77-32 (TSP) - I77-14 (GND)
R - W-B*1
Y - W-B*2
Solar sensor signal (for Front passenger side)
Power switch on (IG)
Solar sensor covered with a cloth
Below 0.8 V
I77-33 (TSD) - I77-14 (GND)
Y - W-B*1
R - W-B*2
Solar sensor signal (for Driver side)
Power switch on (IG)
Solar sensor subjected to electric light
0.8 to 4.3 V
I77-33 (TSD) - I77-14 (GND)
Y - W-B*1
R - W-B*2
Solar sensor signal (for Driver side)
Power switch on (IG)
Solar sensor covered with a cloth
Below 0.8 V
I77-34 (SG-1) - Body ground
LG - Body ground
Ground for room temperature sensor
Always
Below 1 V
I77-37 (LIN1) - I77-14 (GND)
V - W-B
LIN communication signal
Power switch on (IG)
Pulse generation
I77-39 (NANO) - I77-14 (GND)
R - W-B
Ion generator operation signal
Power switch on (IG)
Blower switch: LO
Below 1 V
I77-39 (NANO) - I77-14 (GND)
R - W-B
Ion generator operation signal
Power switch on (IG)
Blower switch: OFF
4.75 to 5.25 V
z1-2 (BUS G) - Body ground
-
Ground for BUS IC
Always
Below 1 V
z1-3 (BUS) - z1-2 (BUS G)
-
BUS IC control signal
Power switch on (IG)
Pulse generation
z1-4 (B BUS) - z1-2 (BUS G)
-
Power supply for BUS IC
Power switch off
11 to 14 V
z1-5 (SGA) - Body ground
-
Ground for evaporator temperature sensor
Always
Below 1 V
z1-6 (TEA) - z1-5 (SGA)
-
Evaporator temperature sensor signal
Power switch on (IG)
Evaporator temperature: 0°C (32°F)
1.7 to 2.1 V
z1-6 (TEA) - z1-5 (SGA)
-
Evaporator temperature sensor signal
Power switch on (IG)
Evaporator temperature: 15°C (59°F)
0.9 to 1.3 V
  1. *1: for RHD
  2. *2: for LHD


    E103396E01
  1. Waveform 1:
    Item
    Content
    Terminal No.
    I77-22 (BLW) - I77-14 (GND)
    Tool Setting
    1 V/DIV., 500 μs/DIV.
    Vehicle Condition
    Power switch on (IG)
    Blower switch: LO


POWER MANAGEMENT CONTROL ECU (Click here)

INVERTER WITH CONVERTER ASSEMBLY (Click here)

AIR CONDITIONING PANEL (HEATER CONTROL SWITCH BOARD)

E182384E04

HINT:
Check from the rear of the connector while it is connected to the air conditioning panel (heater control switch board).


Terminal No.
(Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
I56-2 (IG+) - I56-6 (GND)
R - W-B
Power source (IG)
Power switch off
Below 1 V
I56-2 (IG+) - I56-6 (GND)
R - W-B
Power source (IG)
Power switch on (IG)
11 to 14 V
I56-6 (GND) - Body ground
W-B - Body ground
Ground for air conditioning panel (heater control switch board)
Always
Below 1 V
I56-9 (LIN1) - Body ground
V - Body ground
LIN communication signal
Power switch on (IG)
Pulse generation
I56-11 (ILL+) - I56-15 (ILL-)
G - W-B
Light control switch signal
Light control switch off
Below 1 V
I56-11 (ILL+) - I56-15 (ILL-)
G - W-B
Light control switch signal
Light control switch tail or head position
11 to 14 V
I56-15 (ILL-) - Body ground
W-B - Body ground
Ground for air conditioning panel (heater control switch board) illumination
Always
Below 1 V