Home › Power Source / Network › POWER DISTRIBUTION › MAIN BODY ECU

MAIN BODY ECU > INSTALLATION

for Preparation Click here



1. INSTALL MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)

NOTICE:
  1. Make sure that no foreign matter gets on the connecting surfaces.
  2. Do not touch the ECU connector.



    B292882E01
  1. Insert the main body ECU (multiplex network body ECU) up to the position where it contacts the housing sidewall of the guide as shown in the illustration.
    Text in Illustration 
    *1
    Housing Sidewall
    *a
    20°

    HINT:
    Make sure to keep the angle 20° or more as shown in the illustration.



    B292883E01
  1. Slide the guide of the main body ECU (multiplex network body ECU) along the housing sidewall so that it contacts the junction block fuses as shown in the illustration.
    Text in Illustration 
    *1
    Housing Sidewall
    *2
    Junction Block Fuse



    B292884E01
  1. While keeping the main body ECU (multiplex network body ECU) in contact with side A of the junction block (axis of rotation), rotate it downward as shown in the illustration.
    Text in Illustration 
    *1
    Side A Contact Portion



    B292885E01
  1. Press the push area until the claw engages to install the main body ECU (multiplex network body ECU).
    Text in Illustration 
    *1
    Push Area

    NOTICE:
    1. Make sure to press only the push area.
    2. Confirm the engagement of the main body ECU (multiplex network body ECU) and junction block by listening for the lock sound.

    HINT:
    If a lock sound cannot be heard, visually check the lock part engagement. The engagement can also be confirmed if the main body ECU (multiplex network body ECU) and junction block are flush.



2. INSTALL INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    B279023
  1. Engage the claw to connect the connector as shown in the illustration.

    NOTICE:
    Be sure to engage the connector securely.



    B279021
  1. Engage the claw to lock the connector lock as shown in the illustration.



    B279019
  1. Engage the claw to connect the connector as shown in the illustration.

    NOTICE:
    Be sure to engage the connector securely.

  1. for LHD:

    1. Install the instrument panel junction block assembly with the bolt and 2 nuts.

      Torque:
      8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

    2. Connect the 5 connectors.

      NOTICE:
      Be sure to engage each connector securely.

  1. for RHD:

    1. Engage the claw to install the wiring harness clamp bracket.

    2. Install the nut.

      Torque:
      8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

    3. Install the instrument panel junction block assembly with the bolt and nut.

      Torque:
      8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

    4. Connect the 5 connectors.

      NOTICE:
      Be sure to engage each connector securely.



3. INSTALL POWER MANAGEMENT CONTROL ECU
(Click here)