DTC P071014 Transmission Fluid Temperature Sensor "A" Circuit Short to Ground or Open |

| DTC No. | DTC Detection Condition | Trouble Area |
| P071014 | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
| DATA LIST |
Warm up the engine.
Turn the engine switch off.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Transmission / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature No.1 | ATF temperature sensor value/ Min.: -40°C (-40°F) Max.: 150°C (302°F) |
| If the value is -40°C (-40°F) or 150°C (302°F), the ATF temperature sensor circuit is open or shorted. |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.CHECK HARNESS AND CONNECTOR (ATF TEMPERATURE SENSOR CIRCUIT) |
Disconnect the E96 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E96-84 (THO1) - E96-83 (ETHO) | Always | 79 Ω to 156 kΩ |
| E96-84 (THO1) - Body ground and other terminals | Always | 10 kΩ or higher |
| E96-83 (ETHO) - Body ground and other terminals | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR) |
Disconnect the E8 connector from the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E96-84 (THO1) or E8-13 (OIL) - Body ground and other terminals | Always | 10 kΩ or higher |
| E96-83 (ETHO) or E8-12 (E2) - Body ground and other terminals | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) |
![]() |
Remove the wiring harness connector.
| *a | Component without harness connected (Transmission Wire) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A-17 (E2) - A-18 (THO1) | Always | 79 Ω to 156 kΩ |
| A-17 (E2) - Body ground and other terminals | Always | 10 kΩ or higher |
| A-18 (THO1) - Body ground and other terminals | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | ||
| ||