Home › Drivetrain ยท U761E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

AUTOMATIC TRANSAXLE SYSTEM > PRECAUTION

for Preparation Click here



1.PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable from the negative (-) battery terminal, initialize the following system(s) after the cable is reconnected:

System Name
See Procedure
Parking Assist Monitor System
Click here


2.PROCEDURES NECESSARY WHEN ECU OR OTHER PARTS ARE REPLACED

NOTICE:
  1. If automatic transaxle parts are replaced, perform the following as necessary referring to the table below:
    1. Registration of the transaxle compensation code (Click here).
    2. Initialization of the transaxle compensation code (Click here).
    3. Reset Memory (learned values) (Click here).
    4. Road test (Click here).

      Parts Replacement Compensation Table 
      Replaced Part
      Transaxle Compensation Code
      Reset Memory (Learned Values)
      Road Test
      Automatic Transaxle Assembly
      Input
      Reset
      Necessary
      Transmission Valve Body Assembly
      Initialize
      Reset
      Necessary
      Shift Solenoid Valve SL1 and/or SL2
      -
      -
      Necessary
      Shift Solenoid Valve SL3 and/or SL4
      Initialize
      Reset
      Necessary
      ECM
      (If possible, read the transaxle compensation code from the previous ECM)
      Possible
      Input (Into the new ECM)
      Reset
      Necessary
      Impossible
      Initialize
      Reset
      Necessary
  2. Reset Memory cannot be completed by only disconnecting and reconnecting the cable to the negative (-) battery terminal.


3.HANDLING PRECAUTIONS

CAUTION:
When using compressed air, always aim away from yourself to prevent Automatic Transmission Fluid (ATF) or kerosene from spraying on your face.

NOTICE:
  1. The automatic transaxle is composed of precision-made parts. Careful inspection before reassembly is necessary because even a small nick could cause fluid leakage or affect performance.
  2. The procedures are organized so that you work on only one component group at a time. This will help avoid confusion with similar-looking parts of different sub-assemblies being on your workbench at the same time.
  3. The component groups are inspected and repaired from the converter housing side.
  4. Whenever possible, complete the inspection, repair and reassembly before proceeding to the next component group. If a defect is found in a certain component group during reassembly, inspect and repair this group immediately. If a component group cannot be assembled because parts are being ordered, be sure to keep all parts of the group in a separate container while proceeding with disassembly, inspection, repair and reassembly of other component groups.
  5. Use of Toyota Genuine ATF WS is recommended.
  6. All disassembled parts should be cleaned, and compressed air should be blown through any fluid passages and holes.
  7. Dry all parts with compressed air. Never use a piece of cloth.
  8. The recommended ATF or kerosene should be used for cleaning.
  9. After cleaning, the parts should be arranged in the order they were removed for efficient inspection, repair and reassembly.
  10. New discs for the brakes and clutches must be soaked in ATF for at least 15 minutes before reassembly.
  11. All oil seal rings, clutch discs, clutch plates, rotating parts, and sliding surfaces should be coated with ATF prior to reassembly.
  12. All old gaskets and rubber O-rings must be replaced.
  13. Do not apply adhesive cement to gaskets or similar parts.
  14. Make sure that the ends of snap rings are not aligned with any cutouts. Make sure that snap rings are correctly installed into the grooves.
  15. If a worn bushing is to be replaced, the sub-assembly containing the bushing must also be replaced.
  16. Check the thrust bearings and races for wear or damage. Replace them if necessary.
  17. Use petroleum jelly to keep parts in place.
  18. When working with seal packing (FIPG), observe the following:
    1. Using a razor blade and a gasket scraper, remove all of the old seal packing (FIPG) from the gasket surface.
    2. Thoroughly clean all components to remove any seal packing (FIPG).
    3. Clean both sealing surfaces with a non-residue solvent.
    4. Parts must be reassembled within 10 minutes of application. Otherwise, the seal packing (FIPG) must be removed and reapplied.