DTC P271313 Pressure Control Solenoid "D" Circuit Open |
| DTC No. | DTC Detection Condition | Trouble Area |
| P271313 | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|

| 1.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLT CIRCUIT) |
Disconnect the E96 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E96-1 (SLT+) - E96-31 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| E96-1 (SLT+) - Body ground and other terminals | Always | 10 kΩ or higher |
| E96-31 (SLT-) - Body ground and other terminals | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR) |
Disconnect the E8 connector from the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E96-1 (SLT+) - E8-15 (SLT+) | Always | Below 1 Ω |
| E96-31 (SLT-) - E8-7 (SLT-) | Always | Below 1 Ω |
| E96-1 (SLT+) or E8-15 (SLT+) - Body ground and other terminals | Always | 10 kΩ or higher |
| E96-31 (SLT-) or E8-7 (SLT-) - Body ground and other terminals | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.INSPECT TRANSMISSION WIRE (SLT) |
![]() |
Remove the wiring harness connector.
| *a | Component without harness connected (Transmission Wire) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A-12 (SLT+) - A-7 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| A-12 (SLT+) - Body ground and other terminals | Always | 10 kΩ or higher |
| A-7 (SLT-) - Body ground and other terminals | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 4.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove the shift solenoid valve SLT.
| *1 | Shift Solenoid Valve SLT |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Check that the valve moves and makes an operating sound.
|
| ||||
| OK | ||
| ||