CHARGING SYSTEM > PRECAUTION

for Preparation Click here



1.INITIALIZATION

NOTICE:
When the cable is disconnected from the negative (-) battery terminal, initialize the following system after the cable is reconnected.


System Name
See Procedure
Parking Assist Monitor System
Click here

2.CHARGING SYSTEM PRECAUTION

NOTICE:
  1. Check that the battery cables are connected to the correct terminals.
  2. Disconnect the battery cables when the battery is given a quick charge.
  3. Do not perform tests with a high voltage insulation resistance tester.
  4. Never disconnect the battery cables while the engine is running.
  5. Check that the charging cable nuts are tightened on terminal B of the generator assembly and on the engine room relay block and junction block assembly.