DTC C1ABD Short to +B in Buzzer |
DTC C1ABE Short to GND or Open in Buzzer |
| DTC No. | DTC Detection Condition | Trouble Area |
| C1ABD | When either of the following conditions is met:
|
|
| C1ABE | When either of the following conditions is met:
|
|

| 1.CHECK DTC |
Clear the DTCs (Click here).
Recheck for DTCs and check if the same DTC is output again.
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (BATTERY, BLIND SPOT MONITOR SENSOR LH - RCTA BUZZER (BLIND SPOT MONITOR BUZZER)) |
Disconnect the T17 blind spot monitor sensor LH connector.
Disconnect the N42 RCTA buzzer (blind spot monitor buzzer) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| N42-2 (BZN) - T17-3 (BUZ) | Always | Below 1 Ω |
| N42-2 (BZN) - Body ground | Always | 10 kΩ or higher |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| N42-1 (BZP) - Body ground | Ignition switch ON | 11 to 14 V |
| N42-1 (BZP) - Body ground | Ignition switch off | Below 1 V |
|
| ||||
| OK | |
| 3.REPLACE RCTA BUZZER (BLIND SPOT MONITOR BUZZER) |
Replace the RCTA buzzer (blind spot monitor buzzer) with a new or known good one (Click here).
| NEXT | |
| 4.CHECK DTC |
Clear the DTCs (Click here).
Recheck for DTCs and check if the same DTC is output again.
|
| ||||
| OK | ||
| ||