Home › Drivetrain ยท U660E AUTOMATIC TRANSMISSION / TRANSAXLE › TCM

TCM > INSTALLATION

for Preparation Click here



1. INSTALL TCM
  1. Install the TCM to the automatic transaxle assembly.



    C241670E01
  1. Install and tighten the 2 bolts in the order shown in the illustration.

    Torque:
    11 N*m{ 115 kgf*cm , 8 ft.*lbf }



    C239667
  1. Connect the connector to the TCM.

  1. Turn the lock lever and secure the connector with the lock lever.



2. INSTALL INLET NO. 1 AIR CLEANER


    A256227
  1. Install the inlet No. 1 air cleaner to the intake air resonator sub-assembly.

  1. Engage the pin to the radiator support.



3. INSTALL BATTERY
  1. Install the battery and battery tray.

  1. Install the battery clamp with the bolt and nut.

    Torque:
    Bolt:
    9.0 N*m{ 92 kgf*cm , 80 in.*lbf }
    Nut:
    3.5 N*m{ 36 kgf*cm , 31 in.*lbf }

  1. Connect the positive (+) cable to the positive (+) battery terminal.

    Torque:
    6.5 N*m{ 66 kgf*cm , 58 in.*lbf }



4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY


    A255422E01
  1. Install the air cleaner case sub-assembly to the inlet No. 1 air cleaner.

  1. Insert the projection of the air cleaner case sub-assembly to the hole of the No. 2 air cleaner bracket as shown in the illustration.
    Text in Illustration 
    *1
    Air Cleaner Case Sub-assembly
    *2
    Inlet No. 1 Air Cleaner
    *a
    Projection
    *b
    Hole

  1. Tighten the 2 bolts.

    Torque:
    5.0 N*m{ 51 kgf*cm , 44 in.*lbf }

  1. Connect the wire harness clamp, connector, vacuum hose and No. 1 fuel vapor feed hose.



5. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY


6. INSTALL AIR CLEANER CAP SUB-ASSEMBLY
  1. Connect the air cleaner cap sub-assembly to the throttle with motor body assembly with the hose clamp.

  1. Install the air cleaner cap with hose to the air cleaner case with the 2 clamps.

  1. Connect the wire harness clamp and mass air flow meter connector.

  1. Connect the 3 hoses.

  1. Connect the ventilation hose.

  1. Connect the mass air flow meter connector and wire harness clamp.



7. INSTALL INLET NO. 2 AIR CLEANER
  1. Install the inlet No. 2 air cleaner to the air cleaner case sub-assembly with the 2 bolts.

    Torque:
    8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

  1. Connect the 2 wire harness clamps and vacuum hose clamp.



8. INSTALL COOL AIR INTAKE DUCT SEAL
  1. Install the cool air intake duct seal with the 9 clips.



9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



10. CHECK AUTOMATIC TRANSAXLE SYSTEM

NOTICE:
If automatic transmission parts have been replaced, refer to Parts Replacement Compensation Table to determine if any additional operations are necessary (Click here).