Home › Power Source / Network ยท POWER DISTRIBUTION › INTEGRATION RELAY

INTEGRATION RELAY > INSTALLATION

for Preparation Click here



1. INSTALL ENGINE ROOM JUNCTION BLOCK ASSEMBLY
  1. Connect the 2 connectors.



    B279034
  1. Connect the 4 connectors to the engine room relay block assembly.

  1. Engage the 2 claws to install the engine room junction block assembly.



2. INSTALL NO. 1 RELAY BLOCK COVER


    B279032
  1. Engage the 2 claws to install the No. 1 relay block cover.



3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).