DTC P010515 Manifold Absolute Pressure / Barometric Pressure Sensor Circuit Short to Battery or Open |
| DTC No. | DTC Detection Condition | Trouble Area |
| P010515 | The manifold absolute pressure sensor output voltage is higher than 4.5 V for 0.5 seconds or more (1 trip detection logic). |
|
| DTC No. | Intake Manifold Absolute Pressure | Malfunction |
| P010515 | Approximately 130 kPa(abs) [975 mmHg(abs)] or higher |
|
| Frequency of Operation | Continuous |
| GTS Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.CHECK TERMINAL VOLTAGE (POWER SOURCE OF MANIFOLD ABSOLUTE PRESSURE SENSOR) |
![]() |
Disconnect the manifold absolute pressure sensor connector.
| *a | Front view of wire harness connector (to Manifold Absolute Pressure Sensor) |
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E95-3 (VC) - E95-1 (E2) | Engine switch on (IG) | 4.75 to 5.25 V |
| E95-2 (PIM) - E95-1 (E2) | Engine switch on (IG) | 3.0 to 5.0 V |
|
| ||||
| OK | |
| 2.REPLACE MANIFOLD ABSOLUTE PRESSURE SENSOR |
Replace the manifold absolute pressure sensor (Click here).
| NEXT | |
| 3.CHECK WHETHER DTC OUTPUT RECURS (DTC P010515) |
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Clear the DTC.
Turn the engine switch off and wait for at least 30 seconds.
Turn the engine switch on (IG).
Turn the GTS on.
Drive the vehicle in accordance with the driving pattern described in the Confirmation Driving Pattern.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
| DTCs are not output | A |
| DTC P010515 is output | B |
|
| ||||
| A | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (MANIFOLD ABSOLUTE PRESSURE SENSOR - ECM) |
Disconnect the manifold absolute pressure sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E95-1 (E2) - E96-137 (EPIM) | Always | Below 1 Ω |
| E95-2 (PIM) - E96-106 (PIM) | Always | Below 1 Ω |
| E95-2 (PIM) or E96-106 (PIM) - Other terminals | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||