Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM
RM33A0E _57 Power Source / Network _065377 NETWORKING _0321446 CAN COMMUNICATION SYSTEM J

NETWORKING  CAN COMMUNICATION SYSTEM  Open in Bus 1 Main Bus Line  


DESCRIPTION

There may be an open circuit in one of the CAN main bus lines when the resistance between terminals 23 (CA1H) and 8 (CA1L) of the central gateway ECU (network gateway ECU) is 70 Ω or higher.

Symptom Trouble Area
Resistance between terminals 23 (CA1H) and 8 (CA1L) of the central gateway ECU (network gateway ECU) is 70 Ω or higher.
·

CAN main bus lines or connector

·

Central gateway ECU (network gateway ECU)

·

No. 1 CAN junction connector

·

No. 5 CAN junction connector



This malfunction is not related to the lines of a CAN branch or to ECUs or sensors connected to a CAN branch.

WIRING DIAGRAM

C382080E01
0.271,4.677 0.729,4.875 0.458,0.198 10 false K76 0.604,4.667 2.563,5.208 1.958,0.542 10 false Central Gateway ECU (Network Gateway ECU) 0.698,3.979 1.156,4.177 0.458,0.198 10 false 120 Ω 1.292,3.625 1.75,3.823 0.458,0.198 10 false CAXH 1.333,4.115 1.792,4.313 0.458,0.198 10 false CAXL 1.823,3.625 2.281,3.823 0.458,0.198 10 false 9 1.802,4.104 2.26,4.302 0.458,0.198 10 false 24 4.75,4.104 5.208,4.302 0.458,0.198 10 false 11 4.781,3.625 5.24,3.823 0.458,0.198 10 false 1 5.917,3.625 6.375,3.823 0.458,0.198 10 false 5 5.875,4.104 6.333,4.302 0.458,0.198 10 false 15 4.615,4.646 5.073,4.844 0.458,0.198 10 false R98 5.906,1.177 6.365,1.375 0.458,0.198 10 false 5 5.875,1.646 6.333,1.844 0.458,0.198 10 false 11 4.781,1.177 5.24,1.375 0.458,0.198 10 false 3 4.792,1.656 5.25,1.854 0.458,0.198 10 false 9 1.823,1.188 2.281,1.385 0.458,0.198 10 false 23 1.833,1.656 2.292,1.854 0.458,0.198 10 false 8 1.281,1.208 1.74,1.406 0.458,0.198 10 false CA1H 1.323,1.677 1.781,1.875 0.458,0.198 10 false CA1L 0.698,1.521 1.156,1.719 0.458,0.198 10 false 120 Ω 4.594,2.198 5.052,2.396 0.458,0.198 10 false A66 4.927,2.198 6.167,2.771 1.24,0.573 10 false No. 1 CAN Junction Connector 4.938,4.646 6.198,5.052 1.26,0.406 10 false No. 5 CAN Junction Connector

CAUTION / NOTICE / HINT

CAUTION:

When performing the confirmation driving pattern, obey all speed limits and traffic laws.


NOTICE:
·

Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING

·

Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.

·

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.

DTC check procedure: Turn the ignition switch to ON and wait for 1 minute or more. Then operate the suspected malfunctioning system and drive the vehicle at 60 km/h (37 mph) or more for 5 minutes or more.

·

After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed as normal.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM



HINT:
·

Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.

·

When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.



PROCEDURE

1.CHECK FOR OPEN IN CAN MAIN BUS LINES (NO. 1 CAN JUNCTION CONNECTOR)
a.

Disconnect the cable from the negative (-) battery terminal.


b.

Disconnect the A66 No. 1 CAN junction connector.


c.

Measure the resistance according to the value(s) in the table below.

C376294C02
1.26,1.313 1.677,1.615 0.417,0.302 3.396,1.354 3.396,0.563 3.396,0.563 3.229,0.563 true 4.104,1.365 4.104,0.542 4.104,0.542 4.271,0.542 true 3.396,1.604 3.396,2.25 3.396,2.25 3.229,2.25 true 4.104,1.604 4.104,2.25 4.104,2.25 4.271,2.25 true 0.115,0.063 0.427,0.26 0.313,0.198 10 false *a 1.354,1.385 1.865,1.656 0.51,0.271 10 false A66 2.615,0.49 3.271,0.771 0.656,0.281 10 false CANH*b 4.365,0.469 5.021,0.75 0.656,0.281 10 false CANH*c 2.656,2.177 3.313,2.458 0.656,0.281 10 false CANL*b 4.365,2.167 5.021,2.448 0.656,0.281 10 false CANL*c
*a Front view of wire harness connector
(to No. 1 CAN Junction Connector)
*b to Central Gateway ECU (Network Gateway ECU)
*c to No. 5 CAN Junction Connector - -


Standard Resistance:
Tester Connection Condition Specified Condition Connected to
A66-3 (CANH) - A66-9 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω Central gateway ECU (network gateway ECU)
A66-5 (CANH) - A66-11 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω No. 5 CAN junction connector



Result:
Result Proceed to
OK A
NG (Line to central gateway ECU (network gateway ECU)) B
NG (Line to No. 5 CAN junction connector) C



A

REPLACE NO. 1 CAN JUNCTION CONNECTOR

B

2.CHECK FOR OPEN IN CAN MAIN BUS LINES (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 1 CAN JUNCTION CONNECTOR)

C

3.CHECK FOR OPEN IN CAN MAIN BUS LINES (NO. 5 CAN JUNCTION CONNECTOR)
2.CHECK FOR OPEN IN CAN MAIN BUS LINES (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 1 CAN JUNCTION CONNECTOR)
a.

Reconnect the A66 No. 1 CAN junction connector.


b.

Disconnect the K76 central gateway ECU (network gateway ECU) connector.


c.
C364670C14
1.479,0.156 1.906,0.385 0.427,0.229 2.719,2.01 2.885,2.01 2.885,2.01 2.885,1.208 true 2.76,0.896 2.75,0.313 2.75,0.313 2.917,0.313 true 2.594,0.906 2.594,0.323 2.594,0.323 2.427,0.323 true 2.542,1.792 2.708,1.792 2.708,1.792 2.708,1.208 true 0.083,0.073 0.396,0.271 0.313,0.198 10 false *a 1.583,0.188 2.042,0.385 0.458,0.198 10 false K76 2.031,0.25 2.646,0.448 0.615,0.198 10 false CA1L 2.146,1.719 2.76,1.917 0.615,0.198 10 false CA1H 2.969,0.24 3.406,0.438 0.438,0.198 10 false CAXH 2.344,1.938 2.958,2.135 0.615,0.198 10 false CAXL
*a Front view of wire harness connector
(to Central Gateway ECU (Network Gateway ECU))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
K76-23 (CA1H) - K76-9 (CAXH) Cable disconnected from negative (-) battery terminal Below 1 Ω
K76-8 (CA1L) - K76-24 (CAXL) Cable disconnected from negative (-) battery terminal Below 1 Ω



Result:
Result
OK
NG



OK

REPLACE CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU)

NG

REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 1 CAN JUNCTION CONNECTOR)

3.CHECK FOR OPEN IN CAN MAIN BUS LINES (NO. 5 CAN JUNCTION CONNECTOR)
a.

Reconnect the A66 No. 1 CAN junction connector.


b.

Disconnect the R98 No. 5 CAN junction connector.


c.

Measure the resistance according to the value(s) in the table below.

C372333C02
1.083,1.25 1.594,1.5 0.51,0.25 2.333,0.76 2.5,0.76 2.5,0.76 2.5,1.344 true 2.344,1.99 2.51,1.99 2.51,1.99 2.51,1.573 true 3.625,0.76 3.458,0.76 3.458,0.76 3.458,1.344 true 3.625,1.99 3.458,1.99 3.458,1.99 3.458,1.573 true 0.115,0.073 0.427,0.271 0.313,0.198 10 false *a 1.771,0.688 2.427,0.948 0.656,0.26 10 false CANH*b 1.802,1.906 2.458,2.167 0.656,0.26 10 false CANL*b 1.208,1.302 1.865,1.563 0.656,0.26 10 false R98 3.708,0.688 4.365,0.948 0.656,0.26 10 false CANH*c 3.708,1.906 4.365,2.167 0.656,0.26 10 false CANL*c
*a Front view of wire harness connector
(to No. 5 CAN Junction Connector)
*b to Central Gateway ECU (Network Gateway ECU)
*c to No. 1 CAN Junction Connector - -


Standard Resistance:
Tester Connection Condition Specified Condition Connected to
R98-1 (CANH) - R98-11 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω Central gateway ECU (network gateway ECU)
R98-5 (CANH) - R98-15 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω No. 1 CAN junction connector



Result:
Result Proceed to
OK A
NG (Line to No. 1 CAN junction connector) B
NG (Line to central gateway ECU (network gateway ECU)) C



A

REPLACE NO. 5 CAN JUNCTION CONNECTOR

B

REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (NO. 5 CAN JUNCTION CONNECTOR - NO. 1 CAN JUNCTION CONNECTOR)

C

4.CHECK FOR OPEN IN CAN MAIN BUS LINES (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 5 CAN JUNCTION CONNECTOR)
4.CHECK FOR OPEN IN CAN MAIN BUS LINES (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 5 CAN JUNCTION CONNECTOR)
a.

Reconnect the R98 No. 5 CAN junction connector.


b.

Disconnect the K76 central gateway ECU (network gateway ECU) connector.


c.
C364670C14
1.479,0.156 1.906,0.385 0.427,0.229 2.719,2.01 2.885,2.01 2.885,2.01 2.885,1.208 true 2.76,0.896 2.75,0.313 2.75,0.313 2.917,0.313 true 2.594,0.906 2.594,0.323 2.594,0.323 2.427,0.323 true 2.542,1.792 2.708,1.792 2.708,1.792 2.708,1.208 true 0.083,0.073 0.396,0.271 0.313,0.198 10 false *a 1.583,0.188 2.042,0.385 0.458,0.198 10 false K76 2.031,0.25 2.646,0.448 0.615,0.198 10 false CA1L 2.146,1.719 2.76,1.917 0.615,0.198 10 false CA1H 2.969,0.24 3.406,0.438 0.438,0.198 10 false CAXH 2.344,1.938 2.958,2.135 0.615,0.198 10 false CAXL
*a Front view of wire harness connector
(to Central Gateway ECU (Network Gateway ECU))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
K76-23 (CA1H) - K76-9 (CAXH) Cable disconnected from negative (-) battery terminal Below 1 Ω
K76-8 (CA1L) - K76-24 (CAXL) Cable disconnected from negative (-) battery terminal Below 1 Ω



Result:
Result
OK
NG



OK

REPLACE CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU)

NG

REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 5 CAN JUNCTION CONNECTOR)