The unlock warning switch assembly turns on when the key is inserted into the ignition key cylinder and turns off when the key is removed.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Key Unlock Warning SW | Unlock warning switch | OFF or ON | OFF: Ignition key not inserted
ON: Ignition key inserted |
- |
| Tester Display |
|---|
| Key Unlock Warning SW |
The GTS display changes correctly in response to the unlock warning switch assembly status.
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>THEFT DETERRENT SYSTEM>PROBLEM SYMPTOMS TABLE
NG
Remove the unlock warning switch assembly.
Click hereVehicle Interior>DOOR LOCK>UNLOCK WARNING SWITCH>REMOVAL
Inspect the unlock warning switch assembly.
Click hereVehicle Interior>DOOR LOCK>UNLOCK WARNING SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the main body ECU (multiplex network body ECU).
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Disconnect the 3A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-41 - MB-3 (KSW) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-41 - K31-1 | Always | Below 1 Ω |
| 3A-41 or K31-1 - Other terminals and body ground | Always | 10 kΩ or higher |
| K31-2 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG