The ion generator sub-assembly operates when the blower switch is on. The air conditioning amplifier assembly sends a drive signal to the ion generator sub-assembly. When the ion generator sub-assembly receives the drive signal and starts to operate, it outputs an operation condition signal to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B14B9 | Open in Ion Generator Circuit | Open or short in ion generator circuit | ·
Harness or connector ·
Ion generator sub-assembly ·
Air conditioning amplifier assembly |
Memorized
(12 min. or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
Inspect the fuses for circuits related to this system before performing the following procedure.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Ion Generator | Ion generator sub-assembly | OFF or ON | - |
| Tester Display |
|---|
| Ion Generator |
Ion generator sub-assembly operates normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the Y1 ion generator sub-assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Y1-1 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| Y1-1 (IG) - Body ground | Ignition switch off | Below 1 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Y1-4 (GND) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the K54 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Y1-3 (IG+) - K54-26 (NAIN) | Always | Below 1 Ω |
| Y1-2 (PCL) - K54-7 (NANO) | Always | Below 1 Ω |
| Y1-3 (IG+) or K54-26 (NAIN) - Other terminals and body ground | Always | 10 kΩ or higher |
| Y1-2 (PCL) or K54-7 (NANO) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the K54 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Y1-3 (IG+) - Body ground | ·
Ignition switch ON ·
Blower switch off |
4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Reconnect the Y1 ion generator sub-assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| K54-26 (NAIN) - Body ground | ·
Ignition switch ON ·
Blower switch off |
Below 2.2 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG